1.General

This command assigns the minimum number of digits needed to determine the service required to the first digit received (pre-translation).

2.Precautions

1.This command is used for the Business Application. AANP/AGNP commands are used for Hotel Applications.

2.The applicable tenant number (TN) range is designated by the ASYD command, SYS1, INDEX8. Enter the tenant number this command effects. If data for this command is common for all tenants (ASYD command, SYS1, INDEX92, bit2=1), assign the TN parameter as data “1” for all tenants.

3.Use the ANPD command to assign the numbering data for physical station numbers, service access code, and/or trunk access code, etc.

3.Data Entry Instructions

1st DC

The first digit of service access code, etc. (0-9, *, #)

NND

The primarily analyzed digits, prior to the ASPAL command. Assign the necessary (Minimum) number of digits for each Access Code basically.

To assign different number of digits (such as "Timing Start" for Telephone number), assign maximum number of digits in this parameter.

TENANT

1st DIGIT CODE

CONNECTION STATUS INDEX NUMBER OF NECESSARY DIGITS BUSY LAMP FIELD

NUMBER

(CI)

(NND)

(BLF)

(TN)

(1st DC)

1-3

MAXIMUM 6 DIGITS

0/1

 

 

 

 

 

 

CI

The status of the “1st DC” dialed

N = Nomal (Idle)

H = Hooking

B = Busy

BLF

Whether the station busy status is monitored by the system or not. This parameter assignment is required when the Busy Lamp Field is installed.

0 = Out of Service

1 = In service