NEC NDA-24298 manual Arti Assignment of Trunk Application Data, CDN Route Number Trunk Data

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 680
Image 680

ARTI : Assignment of Trunk Application Data

ARTI: Assignment of Trunk Application Data

1.General

This command assigns Trunk Application Data.

2.Precautions

1.The ARTD command should be assigned for the external trunk route.

2.The applicable number of the external trunk route is designated by the ASYD command, SYS1, INDEX65.

3.Data Entry Instructions

See data sheet in Section 4.

4.Data Sheet

CDN

 

 

 

ROUTE NUMBER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRUNK DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Assignment of Restart

 

 

 

 

 

1

RST

0

=

Restart Send per Individual Channel

 

 

 

 

1

=

Not used

2 = Not used

 

 

 

 

 

 

 

 

 

 

 

 

3

=

Restart not Send

 

 

 

 

 

 

 

 

 

 

 

 

2

HMT

When assigning this data, always enter zero (0).

0

0

0

0

 

 

 

 

 

 

 

 

 

Call Restriction by Information transfer rate in Bearer

 

 

 

 

 

 

Capability Information Element

 

 

 

 

 

 

 

 

0 =

No restriction

 

 

 

 

 

 

 

 

1 =

Data call restriction (Unrestricted digital,

 

 

 

 

3

TRCRST

 

 

Restricted digital and Video data calls are

 

 

 

 

 

 

 

 

restricted.)

 

 

 

 

 

 

 

 

2 =

Speech call restriction (Speech, 3.1 kHz audio and

 

 

 

 

 

 

 

 

7 kHz audio calls are restricted.)

 

 

 

 

 

 

 

3-15=

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Call Restriction by Information transfer rate in Bearer

 

 

 

 

 

 

Capability Information Element

 

 

 

 

 

 

 

 

0 =

No restriction

 

 

 

 

 

 

 

 

1 =

384 Kbps (H0) call is restricted

 

 

 

 

 

4

TRSRST

 

2 =

1536 Kbps (H11)/1920 Kbps (H12) call is

 

 

 

 

 

 

 

 

restricted.

 

 

 

 

 

 

 

 

3 =

384 Kbps and 1536 (H11)/1920 Kbps (H12) calls

 

 

 

 

 

 

 

 

are restricted.

 

 

 

 

 

 

 

4-15=

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Assignment of Timer T309 for Data Link Failure

 

 

 

 

 

 

0

=

Layer 2 Alarm with T309 for Data Link Failure

 

 

 

 

5

T309LNK

1

=

Layer 2 Alarm [Temporary] with T309 is enabled

 

 

 

 

 

 

2

=

Layer 2 Alarm [Permanent] with T309 is enabled

 

 

 

 

 

 

3

=

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHAPTER 4

NDA-24298

Page 646

Issue 1

Page 680
Image 680
NEC NDA-24298 manual Arti Assignment of Trunk Application Data, This command assigns Trunk Application Data