NEC NDA-24298 manual Ancd Assignment of Night Connection Data, Mg/Ncu/Pkg, Port, Rt/Tk

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 800
Image 800

ANCD : Assignment of Night Connection Data

ANCD: Assignment of Night Connection Data

1.General

This command is used when the Power Failure Transfer (PFT) circuit card is controlled by the external key.

2.Precautions

1.When the “PFT control by the external key” is required, the following data assignments are needed:

(a)AUNT command, TYPE = 2 (PFT)

(b)AEKD command

(c)ANCD command

(d)ACSI command, CSI = 4 (Direct-in Termination (Night Mode))

3.Data Entry Instructions

MG/NCU/PKG

Enter the data assigned by the AUNT command.

PORT

The port parameter corresponds to the circuit number of the PFT card.

MODULE

PFT CARD

PORT NUMBER

ROUTE

TRUNK

REMARKS

GROUP

NUMBER

OF PFT CARD

NUMBER

NUMBER

(MG)

(NCU PKG)

(PORT)

(RT)

(TK)

 

00-31

0-3

0-11

1-255

 

 

RT/TK

Enter the trunk route number (RT) and the trunk number (TK) connected to the corresponding circuit number of PFT card.