APHN : Assignment of Phantom Station Number Data

APHN: Assignment of Phantom Station Number Data

1.General

This command assigns a phantom number for a station.

2.Precautions

1.Numbers that are being used as station or LDN numbers cannot be used as phantom numbers.

2.When an incoming call is terminated to a phantom number, either no station hunting or station hunting depending on the data in the PH parameter is performed if the called station is a member station of a hunt group.

3.A maximum of five phantom numbers can be assigned to a station. (Including individual phantom number and phantom number in a hunting group.)

4.The applicable Tenant Number (TN) range is designated by the ASYD command, SYS1, INDEX8.

5.Data entry is not required in the parameters MODE and STN, since data that has already been assigned is displayed.