NEC NDA-24298 manual Aucdl Assignment of UCD Control Data for LDM

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 718
Image 718

AUCDL : Assignment of UCD Control Data for LDM

AUCDL: Assignment of UCD Control Data for LDM

1.General

This command assigns the miscellaneous data related to the Uniform Call Distribution (UCD) service feature for each Node by using Telephone Number. The data is written in Local Data Memory (LDM).

2.Precautions

1.The UCD member station and UCD pilot (controlling station) station should be assigned by the ASHUL command.

2.This command is used to specify the following UCD related options:

(a)The number of calls in UCD queuing which is used for the UCD Peg Count.

(b)The threshold of the UCD Call Waiting Lamp (which is accommodated on a Dterm) starts to flash.

(c)Denial of the MCI call result text of the call terminated to the UCD group.

3.The following data should also be assigned for UCD - Call Waiting lamp flashing:

ASYD command, SYS1, INDEX 61, b5 = 1 (Call Waiting Display-UCD in Service)

AKYD command, FKY = 47 (UCD Call Waiting Lamp)

4.After the data assignment, the line circuit card which contains the UCD group stations must be initialized (turn the MB key ON/OFF).