NEC NDA-24298 manual Apadn Assignment of PAD Data for NDM

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 647
Image 647

APADN : Assignment of PAD Data for NDM

APADN: Assignment of PAD Data for NDM

1.General

This command assigns PAD control data for tandem connections and trunk to station connections in an FCCS network. The data assigned by this command is written in the Network Data Memory (NDM) of the Network Control Node (NCN), updating the NDM at each Local Node (LN).

2.Precautions

When KIND = S (Station) is designated, assign the dummy data to the parameter “OGPAD”.

3.Data Entry Instructions

KIND

The kinds of connection entering in this parameter are as follows. T=Tandem Connection S=Station

SFC

This parameter is not required when KIND=T (Tandem Connection) is assigned.

 

ICPAD/OGPAD

0=No APADN Setting

1-14=Note

15=PAD OFF (0dB)

Note: Switch setting varies depending on the trunk circuit card. Refer to “Circuit Card Manual”.

 

INCOMING

OUTGOING

SERVICE

 

 

KIND OF

LOGICAL

LOGICAL

FEATURE

INCOMING

OUTGOING

CONNECTION

ROUTE

ROUTE

CLASS

PAD DATA

PAD DATA

(KIND)

NUMBER

NUMBER

(SFC)

(ICPAD)

(OGPAD)

T/S

(ICLGRT)

(OGLGRT)

0-15

1-15

1-15

 

1-899

1-899

 

 

 

ICLGRT

Enter the Logical Route Number of Incoming Route. When KIND=S (Station) is assigned, this parameter is not required.

OGLGRT

Enter the Logical Route Number of Outgoing Route.

NDA-24298CHAPTER 4