NEC NDA-24298 Normally, this, Index is assigned, Data 21 Hex, Sec.-ON, Sec.-OFF, Data 42 Hex

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 203
Image 203

ASYD : Assignment of System Data

 

SYSTEM

 

 

BIT

 

 

 

SYSTEM

DATA

CORRESPONDING

 

 

 

DATA

 

 

 

DATA

(DATA)

 

DATA

 

 

 

INDEX

 

SYSTEM DATA CONTENTS

 

TYPE

00 - FF

 

 

 

 

(SYS)

(INDEX)

(Hex)

DATA

 

 

 

 

 

0 - 31

 

BIT

 

 

 

 

 

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

 

Timer Value for Ringer

 

 

 

 

 

 

ON Time is to be assigned a value from

used for Incoming Trunk

 

 

 

 

 

b1

 

 

 

 

 

Calls (Ringer Pattern 0)

 

 

 

 

 

 

1 Hex to F Hex (1~15). (Unit of Time is

 

 

 

 

 

b2

 

 

 

 

 

Second.)

Note:

Normally, this

 

0

 

 

 

b3

 

 

 

 

 

 

 

 

Index is assigned

 

 

 

 

b4

 

 

 

 

 

 

 

OFF Time is to be assigned a value

 

data 21 Hex.

 

 

 

 

 

b5

 

(1 sec.-ON,

 

 

 

 

 

 

from 1 Hex to F Hex (1~15). (Unit of

 

2 sec.-OFF)

 

 

 

 

 

b6

 

 

 

 

 

 

Time is Second.)

 

 

 

 

 

 

 

b7

 

 

 

 

 

 

 

 

b0

ON Time is to be assigned a value from

Timer Value for Ringer

 

 

 

 

 

b1

used for Station Calls

 

 

 

 

 

 

1 Hex to F Hex (1~15). (Unit of Time is

(Ringer Pattern 1)

 

 

 

 

 

b2

 

 

 

 

 

Second.)

 

 

 

 

 

 

 

3

1

 

 

 

b3

 

 

 

 

 

 

 

 

Note:

Normally, this

 

 

 

b4

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF Time is to be assigned a value

 

Index is assigned

 

 

 

 

 

b5

 

 

 

 

 

 

 

data 42 Hex.

 

 

 

 

 

from 1 Hex to F Hex (1~15). (Unit of

 

 

 

 

 

 

b6

 

(2 sec.-ON,

 

 

 

 

 

Time is Second.)

 

 

 

 

 

 

 

 

 

4 sec.-OFF)

 

 

 

 

 

b7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

Station Release Timer (TS) is to be

 

 

 

 

 

 

 

 

assigned a value from 1 Hex to F Hex

 

 

 

 

 

 

 

b1

 

 

 

 

 

 

 

(1~15). (Release timing when

 

 

 

 

 

 

 

b2

Note:

Normally, this

 

 

 

 

 

connected to an ORT)

 

 

 

 

 

 

Timer Value Setting is (TS) 120 msec.

 

Index is assigned

 

2

 

 

 

b3

 

 

 

 

 

 

 

 

data 91 Hex.

 

 

 

 

b4

Hooking Timer (TL) is to be assigned a

 

 

 

 

 

 

 

(TS = 120 msec.,

 

 

 

 

 

 

value from 1 Hex to F Hex (1~15).

 

TL = 1080 msec.)

 

 

 

 

 

b5

 

 

 

 

 

 

(SHF maximum timing)

 

 

 

 

 

 

b6

 

 

 

 

 

 

 

Timer Value Setting is (TL) 120

 

 

 

 

 

 

 

b7

msec.

 

 

NDA-24298CHAPTER 4

Page 169

Issue 1

Page 203
Image 203
NEC NDA-24298 Normally, this, Index is assigned, Data 21 Hex, Sec.-ON, Sec.-OFF, Data 42 Hex, Data 91 Hex, TS = 120 msec