ARTD : Assignment of Route Class Data

 

 

 

 

 

 

 

 

 

RT

 

 

 

REMARKS

FUNCTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Detailed billing for outgoing in tandem connection.

 

 

 

Assign this for the

56

SMDR3

 

 

 

incoming route (ICRT),

0

=

Required

 

1

=

Not required

 

 

 

 

 

 

 

 

 

if necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heterogeneous Data Trunk

 

 

 

 

 

 

 

 

57

HDT

0

=

Not Heterogeneous Data Trunk

 

 

 

 

 

 

 

1

=

Heterogeneous Data Trunk

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58

CD

Consecutive Dialing

 

 

 

 

 

 

 

 

0

=

Out of Service

1

=

In Service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Common Channel Handler

 

 

 

 

 

 

 

Always assign data “0”

59

CCH

0

=

CCH is not mounted (normal setting)

0

0

0

0

even ISDN/CCIS.

 

 

1

=

CCH is mounted (ISDN or CCIS line )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

TC/EC

 

 

 

 

 

 

 

0

0

0

0 Always assign data “0."

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inter-rearranging signal

 

 

 

 

 

 

 

When assigning this

61

IRE

 

 

 

 

 

 

 

data, always enter zero

1

=

Supervisory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step Call Restriction for Tie Line Call

 

 

 

 

 

62

SCR

0

=

Step call is restricted.

 

 

 

 

 

 

 

 

 

 

1

=

Step call is not restricted.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

LYER1

Layer 1 (For ISDN)

 

 

 

 

 

 

 

0= µ law country

0

=

23B+D

 

1

=

30B+D

 

 

 

 

1= A law country

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User/Net Identification (For ISDN)

 

 

 

 

 

Normally assign data

64

NET

0

=

User Side (normal setting)

 

 

 

 

 

 

 

 

 

 

“0."

 

 

1

=

Network side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interface Specification (For ISDN)

 

 

 

 

 

 

 

 

0

=

No.7

1 = N-ISDN2

2 =

Australia

 

 

 

 

 

 

3

=

INS 1500(NTT)

4

=

ITU (CCITT), ETSI

 

 

 

 

 

 

5

=

AT&T(#4/#5 ESS)

6

=

INS 64 (NTT)

 

 

 

 

65

INT

7

=

NT DMS 100/DMS 250

 

 

 

 

 

 

 

8= Not used

9= TTC Q931 a protocol Tie Line (JAPAN)

10= Q-sig, (ETS 300 172)/IS-11572

11= Seamless

 

 

 

 

Note:

Other than 0=

 

 

Dialed Number Confirmation (For ISDN)

Number of

66

DC

 

0 = Sub Addressing

 

Main Address

 

 

1-15 = DID Addressing Note

 

Digits to be

 

 

 

 

 

translated.

 

 

 

 

 

67

HKS

Hooking Service

 

 

0

= Out of Service

1 = In Service

 

 

 

 

NDA-24298CHAPTER 4