NEC NDA-24298 manual ICM STN Number

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 515
Image 515

AICD : Assignment of Intercom Data

3. Data Entry Instructions

MG No.

Enter the Module Group number of the Intercom group.

A/M

0 = Automatic Intercom

1 = Manual Intercom

TN

Enter the Tenant Number of the Intercom group.

MODULE

GROUP

AUTO/

BRIDGE

 

INTERCOM

SIGNALLING

GROUP

ID

MANUAL

CALL

TENANT

STATION NUMBER

STATION

NUMBER

NUMBER

SIGNALING

RESTRIC-

NUMBER No.

(ICM STN)

NUMBER

(MG No.)

(G-ID)

(A/M)

TION

(TN)

 

(SIG STN)

 

1-50

0/1

(BCR)

 

 

 

 

 

 

0/1

 

 

 

 

 

 

 

 

 

 

1

2

3

G-ID

Enter a unique number for each Intercom group with a range from 1 to 50.

BCR

0 = Restricted

1 = Allowed

SIG STN

Enter the Intercom member stations which can receive an Intercom call.

ICM STN

Enter the Intercom member stations which can originate an Intercom call.