ALRNN : Assignment of Logical Route and Route Class Data for NDM

 

 

 

 

 

 

 

 

 

LOGICAL ROUTE (LGRT) 1-899

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSION POINT CODE (FPC) 1-253

 

 

 

 

 

 

 

REMARKS

 

 

 

 

 

 

 

 

 

 

ROUTE NUMBER (RT) 1-255

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trunk Override Calling

 

 

 

 

 

 

 

 

91

TOCI

0

= Override Inhibited (Calling side).

 

 

 

 

 

 

 

1

= Tie Line Override Service is provided (Calling side).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trunk Override Called

 

 

 

 

 

 

 

 

92

TOCD

0

= Override Inhibited (Called side).

 

 

 

 

 

 

 

1

= Tie Line Override Service is provided (Called side).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

93

ODGD

 

 

 

 

 

 

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

94

RLS

 

 

 

 

 

 

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

Gate Way Data Service

 

 

 

 

 

 

 

 

95

GWD

 

0= Out of Service

1

=

Gate Way System

 

 

 

 

 

 

 

2-15= Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

96

H1

ISDN H1 Switching

 

 

 

0

0

0

0

Always assign data “0.”

0

=

1

=

In Service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

97

DT

 

 

 

 

 

 

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ISDN transmitting information

 

 

 

 

 

 

 

 

 

 

 

0 = Out of Service

 

 

 

 

 

 

 

 

98

CI

 

1 = 16-Digit Caller Number Service, Attribute Informa-

 

 

 

 

 

 

 

tion Notification Service, and Calling Sub-Address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transfer Service

 

 

 

 

 

 

 

 

 

 

2-15= Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

99

OID

 

 

 

 

 

 

0

0

0

0

Always assign data“0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

100

TKS

 

 

 

 

 

 

0

0

0

0

Always assign data“0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pad Control Data 2

 

 

 

 

 

 

 

PAD value can also be set

 

 

 

 

 

 

 

 

 

by switch setting on the

101

PAD2

0-7 =

For Pad value, See the NEAX2400 IPX Circuit Card

 

 

 

 

 

 

 

 

8TLT (Long Line

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Telephone = TELT) card.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

102

TRM

 

 

 

 

 

 

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

103

TRPX

 

 

 

 

 

 

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

104

LDR

 

 

 

 

 

 

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

105

TSC

 

 

 

 

 

 

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

106

SATS

 

 

 

 

 

 

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

107

RVPX

 

 

 

 

 

 

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

108

DQ

 

 

 

 

 

 

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

109

SLOV

Slumber Time Override Service

 

 

 

0

0

0

0

 

0

=

Out of Service

1

=

In Service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System message automatic output when Connection Ac-

 

 

 

 

 

110

SDTO

knowledge signal has not been received.

 

 

 

 

 

 

 

0

=

Out of Service

1

=

In Service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

111

ADVPRA

ISDN PRI Failure Routing Service

 

 

 

 

 

 

This data is valid for

0

=

Out of Service

1

=

In Service

 

 

 

 

dummy routes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

112

IND

Inter-office Name Display

 

 

 

 

 

 

 

 

0

=

Out of Service

1

=

In Service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

113

UUI

 

 

 

 

 

 

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

NDA-24298CHAPTER 4

Page 565

Issue 1

Page 599
Image 599
NEC NDA-24298 manual Pad Control Data

NDA-24298 specifications

The NEC NDA-24298 is a cutting-edge digital signage solution that has rapidly gained recognition in various industries due to its advanced features and capabilities. Designed for both indoor and outdoor applications, this display system integrates modern technologies to deliver vivid imagery and exceptional reliability.

One of the standout features of the NDA-24298 is its high-resolution panel, which supports 4K Ultra HD output. This ensures that content is presented with stunning clarity and detail, making it ideal for advertising, information displays, and event broadcasting. The vibrant color reproduction along with a wide color gamut enhances the viewing experience, captivating audiences and ensuring that messages are conveyed effectively.

Additionally, the NDA-24298 is equipped with high brightness levels, making it suitable for environments with significant ambient light. The ultra-bright display ensures that content remains visible even in direct sunlight, making it perfect for outdoor installations such as shopping plazas, stadiums, and transportation hubs. This capability is bolstered by advanced anti-glare technology, which further enhances visibility and reduces reflections.

In terms of connectivity, the display offers multiple input options including HDMI, DisplayPort, and USB-C, allowing for seamless integration with various media sources. The device also supports network connectivity, enabling remote management and content updates via IP networks. This feature is crucial for businesses requiring dynamic content displays, as it provides the flexibility to change messaging on-the-fly without the need for manual intervention.

The NDA-24298 also prioritizes durability and longevity, featuring a robust build designed to withstand harsh environmental conditions. Its all-weather enclosure protects the internal components from moisture, dust, and temperature extremes, ensuring consistent performance over time.

Furthermore, the display promotes energy efficiency, which is increasingly important for sustainable operations. NEC has implemented smart power management features that help reduce energy consumption without compromising on performance quality.

In summary, the NEC NDA-24298 is an impressive digital signage display that combines high-resolution visuals, durable construction, vibrant colors, and advanced connectivity options. Its adaptability makes it an ideal choice for a broad range of applications, helping businesses to engage their audiences effectively and efficiently. With the NDA-24298, organizations can elevate their communication strategies while reinforcing brand presence and enhancing consumer interaction.