NEC NDA-24298 manual B0~ b7

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 212
Image 212

ASYDL : Assignment of System Data into Local DM (LDM)

 

SYSTEM

 

 

BIT

 

SYSTEM

DATA

CORRESPONDING

 

DATA

 

DATA

(DATA)

 

DATA

 

INDEX

 

SYSTEM DATA CONTENTS

TYPE

00 - FF

 

 

 

(SYS)

(INDEX)

(Hex)

DATA

 

 

 

512 - 1535

 

BIT

 

 

 

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

Fusion Centralized SMDR Service (Polling Method)

 

 

 

 

 

0/1 = No/Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SMDR for Fusion Network station-to-station calls

 

 

 

 

 

b1

0/1 = All Station Calls/Fusion Station Calls only

 

 

 

 

 

Note: Data valid only when ASYDL Index 512 is set.

 

 

 

 

 

 

 

 

 

 

 

 

Valid for IPX Version 2 software or higher.

 

576

 

 

 

 

 

 

 

 

 

b2

SMDR Interface Type

 

 

 

 

 

0/1 = RS232C/LANI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output the System Message related to connection

 

 

 

 

 

b3

down when the system changeover occurs on LAN

 

 

 

 

 

Interface for SMDR.

 

 

 

 

 

 

0/1 = Invalid/Valid

 

 

 

 

 

 

 

 

 

 

 

 

b4 ~ b7

Not used

 

 

 

 

 

 

FPC (Fusion Point Code) of the Center node (CN) for

 

 

 

 

 

 

the Centralized SMDR (Centralized Billing-Fusion).

 

 

 

 

 

 

FPC: 1-253 (01 Hex-FD Hex.)

1

577

 

 

 

b0~ b7

Note: Data 01 Hex-FD Hex should be assigned at

 

 

 

 

 

the Local Node (LN) for the Centralized

 

 

 

 

 

 

 

 

 

 

 

 

Billing-Fusion. Data “00” must be fixedly

 

 

 

 

 

 

assigned at the Center Node (CN) of

 

 

 

 

 

 

Centralized Billing-Fusion.

 

 

 

 

 

 

 

 

 

 

 

 

 

Centralized Billing-Fusion output text format of

 

 

 

 

 

b0

SMDR A

 

 

 

 

 

 

0/1 = ICS format/IPX format

 

 

 

 

 

 

 

 

578

 

 

 

b1 ~ b3

Not used

 

 

 

 

 

b4

0/1 = SMDR A Apparatus with LAN interface is not

 

 

 

 

 

used/used. Note

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5 ~ b7

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

Centralized Billing-Fusion output text format of

 

 

 

 

 

b0

SMDR B

 

 

 

 

 

 

0/1 = ICS format/IPX format

 

 

 

 

 

 

 

 

579

 

 

 

b1 ~ b3

Not used

 

 

 

 

 

b4

0/1= SMDR B Apparatus with LAN interface is not

 

 

 

 

 

used/used. Note

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5 ~ b7

Not used

Note: Assign “1” at the node to which SMDR with LAN interface is connected. If not connected, this data setting is fixed to “0.”

CHAPTER 4

NDA-24298

Page 178

Issue 1

Page 212
Image 212
NEC NDA-24298 manual B0~ b7