NEC NDA-24298 manual See -17and

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 590
Image 590

ALRNN : Assignment of Logical Route and Route Class Data for NDM

LOGICAL ROUTE (LGRT) 1-899

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSION POINT CODE (FPC) 1-253

 

 

 

 

 

 

 

 

REMARKS

 

 

 

 

 

 

 

 

 

 

 

 

 

ROUTE NUMBER (RT) 1-255

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line Signal

 

 

 

 

 

 

 

 

 

 

 

0

=

Loop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

=

Ground Start

C.O. Line

 

 

 

 

 

 

 

 

 

 

2

=

CCH

 

 

 

 

 

 

 

 

 

 

 

3

=

Caller ID (Loop)

 

 

 

 

 

 

 

 

 

 

 

4

=

Loop

 

 

 

 

 

 

 

 

 

 

 

15

LSG

5

=

E&M

 

 

Tie Line

 

 

 

 

 

 

 

 

 

 

6

=

DX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

=

24V4

 

 

 

 

 

 

 

 

 

 

 

8

=

Loop DID

9 - 11 =

Not used

 

 

 

 

 

 

 

 

12 =

Speech Line (for CCIS No. 7 or Bch of ISDN)

 

 

 

 

 

 

 

 

13 =

Signal Line (for CCIS No. 7 or Dch of ISDN)

 

 

 

 

 

 

 

 

14 =

Not used

15 =

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

SMDR2

Detailed Billing Information

 

 

 

 

 

 

 

 

See Figure 4-17and

 

 

 

 

 

 

 

 

Table 4-24.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

H/M

Hotel Service in CCIS No. 7

 

 

 

 

 

 

 

 

 

0

=

Out of Service

1

=

In Service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

MC

 

 

 

 

 

 

 

 

0

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

ANI

E911 - ANI Service

 

 

 

 

 

 

 

 

 

0

=

Out of Service

1

=

In Service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

D

 

 

 

 

 

 

 

 

0

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

MSB

 

 

 

 

 

 

 

 

0

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

MSW

 

 

 

 

 

 

 

 

0

0

0

0

0

Always assign data “0.”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

TR

0

=

 

 

 

 

 

 

 

 

For MFC signaling

1

=

ICPT transfer by group-II signals used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHAPTER 4

NDA-24298

Page 556

Issue 1

Page 590
Image 590