NEC NDA-24298 manual Smdr, Mpc

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 890
Image 890

ACRD : Assignment of Connection Route Class Data for Local Data Memory

4. Data Sheet

 

 

 

CONNECTION RT No.

 

 

 

 

 

 

CDN

 

 

(C_RT) 1-1023

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION (FUNC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TF - Type of Trunk

 

 

 

 

 

 

1

0 - 2 = -

3

3

3

3

3

3

 

3

=

Bothway Trunk (BWT)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TCL - Trunk Class (Fixed “4”)

 

 

 

 

 

 

2

1-3

=

-

4

4

4

4

4

4

4

=

Fusion Trunk

 

 

 

 

 

 

 

 

5-31 = -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RLP - Trunk Release Pattern

 

 

 

 

 

 

 

(Fixed “2”)

 

 

 

 

 

 

3

0-1

= -

2

2

2

2

2

2

2= First party Release

3= -

 

SMDR -

 

 

 

 

 

 

 

Detailed Billing Information

 

 

 

 

 

 

4

(Fixed “0”)

0

0

0

0

0

0

0= SMDR is out of service

1= SMDR is in service

LSG - Line Signal 0-11 = -

512 = B-channel

13 = D-channel 14, 15 = -

PAD - PAD control

0= Depending on the assignment ofPAD parameter in ARTD command.

1= 8 dB for sending, 0dB for receiving.

2= 4 dB

6 3 = 8 dB for sending, 12 dB for receiving.

4= 8 dB

5= Not used

6= Not used

7= 0 dB

Standard data = 7 (0 dB)

TRKS - Trunk Selection Sequence

 

 

 

 

 

 

0

= Select from the trunk which becomes

 

 

 

 

 

 

7

idle first

0

0

0

0

0

0

1= Select from the trunk which becomes idle last

 

TC/EC

 

 

(Fixed “0”)

8

0

=

No MPC/EC

1

=

EC

 

 

2

=

MPC

 

3

=

Not used

CHAPTER 4

NDA-24298

Page 856

Issue 1

Page 890
Image 890