NEC NDA-24298 manual Sup, Mn, Mj, This data is fixed to 00 when Alarm Grade data is

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 132
Image 132

ASYD : Assignment of System Data

 

SYSTEM

 

BIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM

DATA

CORRESPONDING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA

(DATA)

DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDEX

 

 

 

 

 

 

SYSTEM DATA CONTENTS

 

 

 

 

 

 

TYPE

00 FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(SYS)

(INDEX)

(Hex)

DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 511

 

BIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b0

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Backup Call Forwarding and Individual Speed Data to HDD

 

 

 

 

 

b1

(See Index 304)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0/1 = No/Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b2

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b3

Residual link detect

 

 

 

 

 

 

 

 

 

 

90

 

 

 

0/1 = No/Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b4

LP ACT/STBY Changeover (for IPX-UMG system)

 

 

 

 

 

 

 

0/1 = No/Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b5

CMP ACT/STBY Changeover (for IPX-UMG system)

 

 

 

 

 

0/1 = No/Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b6

Not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

b0

Not used

 

 

 

 

 

 

 

 

 

 

 

 

0

 

b1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

b2

Grades of System Message that can be Registered:

 

 

 

 

 

 

 

 

b3

b2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

= Register All System Message Data

 

 

 

 

 

 

 

 

 

 

0

 

1

 

= Register System Message Data higher than grade 1

 

 

 

 

 

 

 

 

 

 

 

(SUP, MN, MJ)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b3

1

 

0

 

= Register System Message Data higher than grade 2

 

 

 

 

 

 

 

 

 

 

(MN, MJ)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

1

 

= Register System Message Data higher than grade 3

 

91

 

 

 

 

 

 

 

 

 

(MJ)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:

This data is fixed to “00” when Alarm Grade data is

 

 

 

 

 

 

 

 

 

 

 

assigned by the ALMG command.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b4

External Supplied Clock to TSW

When one PLO card is

 

 

 

 

 

(12.352M-24CH System No. 0)

to be mounted:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b7

b6

b5

b4

 

 

 

 

 

b5

External Supplied Clock to TSW

 

 

 

 

 

 

(12.352M-24CH System No. 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

1

 

0

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b6

External Supplied Clock to TSW

When two PLO cards

 

 

 

 

 

(12.288M-32CH System No. 0*)

 

 

 

 

 

 

 

 

 

 

 

 

are to be mounted:

 

 

 

 

 

 

External Supplied Clock to TSW

 

 

 

 

 

b7

 

b7

b6

b5

b4

 

 

 

 

 

(12.288M-32CH System No. 1*)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

1

 

1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHAPTER 4

NDA-24298

Page 98

Issue 1

Page 132
Image 132