NEC NDA-24298 manual Astpl Assignment of Signal Translation Pattern for LDM

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 316
Image 316

ASTPL : Assignment of Signal Translation Pattern for LDM

ASTPL: Assignment of Signal Translation Pattern for LDM

1.General

This command assigns the Incoming/Outgoing Selection Translation Pattern Number (PNI/PNO) for incoming or outgoing trunk route. This data is written in Local Data Memory (LDM).

2.Precautions

1.The PNI/PNO is an intermediate parameter to assign additional number (and skip digits) by the AISPL/ AOSPL command.

(a)When IC/OG=I (Incoming) is entered, the additional number is assigned by the AISPL command.

(b)When IC/OG=O (Outgoing) is entered, the additional number and skip digits are assigned by the AOSPL command.

2.The transmit number translation of the OGC/OGCA method outgoing calls are done by ASTPL/AOSPL command. Since the additional number and skip digits can be assigned by the AOPRL /AADCL command for LCR/LCRS method, the ASTPL/AOSPL command may not be required.

3.The system processes ASTPL/AISPL command prior to the numbering plan data. Thus, if the LCR access code is added to the received numbers by the ASTPL/AISPL command, the system processes the LCR related command such as ASPAL/AFRSL /AOPRL.

4.The applicable Tenant Number (TN) range is designated by the ASYD command, SYS1, INDEX8. Enter the tenant number in which this command effects. If data of this command is common for all tenants (ASYDL command, SYS1, INDEX800, bit4,5=1), assign TN parameter as data “1” for all tenants.

3.Data Entry Instructions

IC/OG

I=Incoming

O=Outgoing

PNI

PNI appears when IC/OG=I is entered. Enter any number with a range from 1 to 15.

KIND OF

TENANT

LOGICAL

INCOMING SELECTION

OUTGOING SELECTION

ROUTE

TRANSLATION

TRANSLATION

ASSIGNMENT

NUMBER

NUMBER

PATTERN NUMBER

PATTERN NUMBER

(IC/OG)

(TN)

(LGRT)

(PNI)

(PNO)

I/O

1-63

1-899

1-15

1-15

 

 

I

1

0

0

11

pnip

PNO

PNO

PNO appears when IC/OG=O is entered. Enter any number with a range from 1 to 15.

CHAPTER 4

NDA-24298

Page 282

Issue 1

Page 316
Image 316
NEC NDA-24298 manual Astpl Assignment of Signal Translation Pattern for LDM, Number Pattern Number IC/OG Lgrt PNI