NEC NDA-24298 manual Fcic

Models: NDA-24298

1 1020
Download 1020 pages 51.64 Kb
Page 914
Image 914

ACAN : Assignment of CIC Number Between Adjacent Nodes for Local Data Memory

ACAN: Assignment of CIC Number Between Adjacent Nodes for Local Data Memory

1.General

This command assigns LENS and Fusion Circuit Identification Code (Fusion CIC) numbers on the basis of each Fusion Point Code (FPC).

2.Precautions

1.Before executing this command, confirm that the following assignments have already been completed:

(a)LSG: 12 (the ACRD command) is assigned to the B-channel Route to which the Fusion CIC belongs.

(b)The trunk data for the Fusion CIC is assigned using the ACTK command.

2.The FCIC given to each B-channel should be identical to the originating node and its adjacent node.

3.The available FCIC (Fusion CIC Number) is 1-4095.

4.For detailed information, see the NEAX2400 IPX Fusion Network System Manual.

3.Data Entry Instructions

FPC

FPC is a unique number allotted to each node.

Assign FPC of the adjacent node to this parameter.

FCIC

Fusion CIC number of the adjacent node

C_LENS

LENS of the trunk for B-channel assigned by the ACTK command

FUSION POINT CODE

FUSION CIC NUMBER

 

CONNECTION EQUIPMENT

 

(FPC)

(FCIC)

 

 

 

NUMBER (C_LENS)

 

1-253

1-4095

 

 

 

 

 

 

 

 

10

1

0

0

0

0

1

0

10

2

0

0

0

0

1

1

10

3

0

0

0

0

1

2

REMARKS

CHAPTER 4

NDA-24298

Page 880

Issue 1

Page 914
Image 914
NEC NDA-24298 manual Fcic