ASSIGNMENT

1. From the PBX menu, select Configuration to open the PBX Administration dialog box.

Figure 2-20 PBX Administration

2. Enter a name for the PBX Alias in the PBX Alias box.

Note: You can also define a PBX Alias by selecting the default NEXT-IPX or by modifying any other previously defined Alias from the list in the PBX Alias box. If you select a PBX Alias from the list, its related information displays in the additional fields on this dialog box. You can enter information in the Connect Timeout, Response Timeout, Pacing Timer, and Link Data Log Path fields if necessary. However, the IPX MAT software will run without changing the default data.

3.Select Serial/Direct as the Connection Type.

4.Enter the appropriate FPC (Fusion Link Point Code). 1 is the default value and should be used initially for all new IPX systems. In a Fusion Network, this setting must match the FPC value entered into System Data SYS 1 INDEX 512.

5.Enter 120000 in the Connection Timeout text box.

6.Enter 120000 in the Response Timeout text box.

7.Enter 10000 in the Pacing Timer text box.

8.Clear (Remove) any text from the Link Data Log Path text control.

9.Set COM1 Baud rate to 4800. This is the default PBX value on the initial power up.

10.Leave the Host Name text box blank.

11.Leave the IP Address text box blank.

NDA-24298CHAPTER 2