B Control panel menus | 213 | ||
or browsing the embedded Web server). |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
Item | Options | Values | Explanation |
|
|
|
|
TCP/IP | ENABLE | ON | Selects whether the TCP/IP protocol is enabled (ON) or |
|
| OFF | disabled (OFF). |
| CONFIG METHOD | BOOTP | Selects whether the TCP/IP configuration parameters are set |
|
| DHCP | automatically from a network server either using BootP |
|
| MANUAL | (Bootstrap Protocol), DHCP (Dynamic Host Configuration |
|
|
| Protocol), or manually from the EIO submenu. |
| MANUAL |
| Provides access to parameters that can manually configured |
| SETTINGS |
| from the product control panel. For manual configuration, |
|
|
| CONFIG METHOD must be set to MANUAL. |
|
| IP ADDRESS | The unique IP address of the product, where n is a value from |
|
| n.n.n.n | 0 to 255. |
|
| SUBNET MASK | The subnet mask for the product, where m is a value from 0 to |
|
| m.m.m.m | 255. The mask is applied to IP addresses to uniquely identify |
|
|
| subnetworks and nodes. |
|
| SYSLOG SERVER | The IP address of the syslog server used to receive and log |
|
| n.n.n.n | syslog messages. |
|
| DEFAULT | The IP address of the gateway or router used for |
|
| GATEWAY | communications with other networks. |
|
| n.n.n.n |
|
|
| IDLE TIMEOUT | The timeout value (in seconds) after an idle TCP print data |
|
| xx | connection is automatically closed. The default value is 270 |
|
|
| seconds. 0 disables the timeout. |