Appendix D Alternator Protection
The 550 controller has
The current and time limits are defined by actual test data and are maintained in the personality parameter file. Although the equation for detecting a fault is proprietary, some of the important limits are shown below for informational purposes.
Rated Current | Time Delay |
|
|
200% | 40 seconds |
|
|
300% | 10 seconds |
|
|
425% | 5 seconds |
|
|
950% | 1 second |
208 Appendix |
|