Factory-Defined Settings

 

 

 

 

 

Relay

 

 

 

 

Inhibit

 

Status Event

Refer

 

 

Driver

Alarm

 

 

Default

Time

Time

to

 

 

Output

 

 

Delay

Delay

or Fault

Menu

Digital Display

 

(RDO)

Horn

Lamp

Range Setting

Selection

(sec.)

(sec.)

 

 

 

 

 

 

 

 

 

 

 

Digital Aux. Input

9, 10

D12

 

 

On

Warning

Fixed

2 sec.

 

 

D12 Detonation

 

DETON

 

 

 

 

 

inhibit,

 

 

Warning ]

 

WARNING

 

 

 

 

 

0 sec. delay

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Aux. Input

9, 10

D13

 

 

On

Shutdown

Fixed

0 sec.

 

 

D13 Detonation

 

DETON

 

 

 

 

 

inhibit,

 

 

Sensing Module

 

SHUTDOWN

 

 

 

 

 

0 sec. delay

 

 

(DSM) Shutdown ]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Aux. Input

9, 10

D13

 

 

On

Shutdown

Fixed

0 sec.

 

 

D13 Knock Detection

 

KNOCK

 

 

 

 

 

inhibit,

 

 

Module (KDM)

 

SHUTDOWN

 

 

 

 

 

0 sec. delay

 

 

Shutdown ]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Aux. Input D14

9, 10

D14 LOW

 

RDO-19

On

Shutdown

Fixed

30 sec.

 

 

Low Coolant Level,

 

COOLANT LVL

 

 

 

 

 

inhibit,

 

 

(with LCL switch) **

 

 

 

 

 

 

 

5 sec. delay

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Aux. Input

9, 10

D15 REMOTE

 

 

On

Shutdown

 

0 sec.

 

 

D15 Remote

 

SHUTDOWN

 

 

 

 

 

inhibit,

 

 

Shutdown

 

 

 

 

 

 

 

0 sec. delay

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Aux. Input

9, 10

 

 

 

 

 

 

 

 

 

D16 Remote Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Aux. Input

9, 10

 

 

 

 

 

 

 

 

 

D17 VAR/PF mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Aux. Input

9, 10

 

 

 

 

 

 

 

 

 

D18 Voltage Lower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Aux. Input

9, 10

 

 

 

 

 

 

 

 

 

D19 Voltage Raise

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Aux. Input

9, 10

D20

 

RDO-23 *

On

Shutdown

Fixed

0 sec.

 

 

D20 Air Damper

 

AIR DAMPER

 

(lead 56)

 

 

 

inhibit,

 

 

Indicator (if used) **

 

 

 

 

 

 

 

0 sec. delay

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Aux. Input

9, 10

D21

 

RDO-21

Off

Warning

Fixed inhibit time

0 sec.

 

0--600

D21 Idle (speed)

 

IDLE MODE

 

 

 

 

 

inhibit,

 

or 9:99

Mode Function

 

ACTIVE

 

 

 

 

 

60 sec.

 

for

 

 

 

 

 

 

 

 

 

delay

 

infinity

 

 

 

 

 

 

 

 

 

 

 

ECM Red Alarm

10

ECM RED

 

 

On

Shutdown

 

 

 

 

(was MDEC Red

 

ALARM

 

 

 

 

 

 

 

 

Alarm) [[

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ECM Yellow Alarm

10

ECM YELLOW

 

 

On

Warning

 

 

 

 

(was MDEC Yellow

 

ALARM

 

 

 

 

 

 

 

 

Alarm) [[

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EEPROM Write

10

EEPROM WRITE

 

 

On

Shutdown

 

 

 

 

Failure

 

FAILURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Emergency Stop

10

EMERGENCY

 

RDO-14

On

Shutdown

 

 

 

 

Shutdown

 

STOP

 

(lead 48)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Engine Cooldown

 

 

 

 

 

 

 

 

 

 

(see Time Delay--)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Engine Derate Active

10

ENGINE

 

 

 

 

 

 

 

 

 

 

 

DERATE

 

 

 

 

 

 

 

 

 

 

 

ACTIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Engine) J1939 CAN

10

J1939 CAN

 

 

On

Shutdown

 

 

 

 

Shutdown

 

SHUTDOWN

 

 

 

 

 

 

 

 

(ECM only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Engine Stalled

10

ENGINE

 

 

On

Shutdown

 

 

 

 

(ECM only)

 

STALLED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Engine Start

 

 

 

 

 

 

 

 

 

 

(see Time Delay--)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EPS (Emergency

10

EPS

 

RDO-22

Off

Warning

Fixed

1% of rated

 

 

Power System)

 

SUPPLYING

 

 

 

 

 

line current

 

 

Supplying Load

 

LOAD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field Overvoltage

 

 

 

 

 

 

 

 

 

 

(see D04)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

All models, except Waukesha-powered models.

 

 

** NFPA applications

 

 

 

[

Non-paralleling applications

 

 

 

 

[[ DDC/MTU engine with MDEC/ADEC

 

 

]

Waukesha-powered models

 

 

 

 

]] FAA only

 

 

 

w

Paralleling applications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26 Section 1 Specifications and Features

TP-6200 10/12

Page 26