To answer a call:

1 Touch On/Quiet on the headset adapter.

To mute the microphone:

1 Hold down On/Quiet on the headset adapter.

To hang up:

1 Touch Off on the headset adapter.

The green light next to On/Quiet goes off.

In-Range, Out-of-Building Voice Termianl and Protectors

DESCRIPTION

You can place a voice terminal in another location, outside of the main

 

building, but within 1000 feet of the MERLIN 11 system control unit. In order

 

to protect both this In-Range, Out-of-Building (IROB) voice terminal and the

 

control unit from exposure to lightning, contact with power lines, or power

 

currents induced by nearby power lines, you must also install two Model TII

 

341 IROB protectors. See the example in Figure 2-24. Install one of the IROB

 

protectors where the cable from the control unit leaves the building, and the

 

other where the cable enters the building in which the IROB voice terminal

 

is located.

 

 

 

 

FIGURE 2-24 Basic IROB voice terminal and protector configuration.

 

IROB

I R O B

 

protector

protector

 

 

Interbuilding

 

 

wiring

I

- - - - -

Approved ground

CONSIDERATIONS

These protectors must be mounted indoors,

 

An approved electrical ground, such as a ground installed by the power

 

service company, grounded building steel, or concrete-encased ground,

 

is required for proper operation of the IROB protector. (For more

 

information about approved ground, see the instructions that come with

 

your IROB protectors.)

2-182MERLIN II System Features