Mitsumi electronic 55K Parameter Factory Setting Remarks, 9999 1 to No restart, 164, 165 120%

Models: FR-F520-0.75K 55K

1 217
Download 217 pages 2.41 Kb
Page 102
Image 102

PARAMETERS

4.2.24Automatic restart after instantaneous power failure (Pr. 57, Pr. 58, Pr. 162 to Pr. 165)

Pr. 57 "restart coasting time

Pr. 58 "restart cushion time

Pr.162 "Automatic restart after instantaneous power failure selection" Pr.163 "First cushion time for restart"

Pr.164 "First cushion voltage for restart"

Pr.165 "Restart stall prevention operation level"

#You can restart the inverter without stopping the motor (with the motor coasting) when the commercial power supply is switched to the inverter operation or when the power is restored after an instantaneous power failure. (When restart operation is set to be enabled, an automatic restart after instantaneous power failure is made without the E.UVT (undervoltage protection) or E.IPF (instantaneous power failure protection) alarm output signal being output at occurrence of an instantaneous power failure.)

Parameter

Factory

Setting

Remarks

 

 

 

 

Number

Setting

Range

 

 

 

 

 

 

 

 

 

57

9999

0, 0.1 to

9999: No restart

 

 

 

 

5 s, 9999

 

 

 

 

 

 

 

 

 

 

 

58

1.0 s

0 to 60 s

 

 

NFB

 

 

 

0: Frequency

 

 

 

 

 

 

 

 

 

 

 

162

0

0, 1

search

 

 

 

 

 

 

 

 

1: No frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

search

 

 

 

 

163

0 s

0 to 20 s

 

 

 

 

 

164

0%

0 to 100%

 

 

 

 

 

165

120%

0 to 150%

 

 

 

 

 

 

 

MC2

MC1

 

MC3

R L1

U

 

S L2

V

IM

T L3

W

 

R1 L11

 

S1 L21

 

STF

 

CS

 

SD

MC switching sequence

 

When Pr.162 = 0 (with frequency search)

Instantaneous power failure time

Power supply (R, S, T)

Motor speed N (r/min)

Inverter output frequency

f (Hz)

CS

 

Connect CS-SD for use of only

SD

 

automatic restart after instantaneous

 

power failure.

 

 

 

4

When Pr.162 = 1 (without frequency search)

Instantaneous power failure time

Power supply (R, S, T)

Motor speed

N (r/min)

Inverter output frequency

f (Hz)

Inverter output

 

Inverter output

 

 

voltage

 

voltage

 

 

 

E (V)

 

E (V)

 

 

 

 

 

 

Cushion voltage time (value set in Pr. 58)

 

Cushion voltage time

[Coasting time] + [speed detection time]

 

Coasting time

Approx. 5s

Pr. 58 setting

 

 

Pr. 57 setting

 

Pr. 57 setting

 

89