Mitsumi electronic 55K, FR-F520-0.75K instruction manual Additional instructions

Models: FR-F520-0.75K 55K

1 217
Download 217 pages 2.41 Kb
Page 4
Image 4

4. Additional instructions

Also note the following points to prevent an accidental failure, injury, electric shock, etc.:

(1) Transportation and installation

CAUTION

!When carrying products, use correct lifting gear to prevent injury.

!Do not stack the inverter boxes higher than the number recommended.

!Ensure that installation position and material can withstand the weight of the inverter. Install according to the information in the Instruction Manual.

!Do not operate if the inverter is damaged or has parts missing.

!Do not hold the inverter by the front cover; it may fall off.

!Do not stand or rest heavy objects on the inverter.

!Check the inverter mounting orientation is correct.

!Prevent screws, wire fragments, conductive bodies, oil or other flammable substances from entering the inverter.

!Do not drop the inverter, or subject it to impact.

!Use the inverter under the following environmental conditions:

 

Ambient temperature

-10°C to +50° C (14° F to 122° F) (non-freezing)

 

(-10°C to +40° C (14° F to 104° F) with FR-A5CV""attachment)

 

 

Environment

Ambient humidity

90%RH or less (non-condensing)

Storage temperature

-20°C to +65° C* (-4°F to 149° F)

Ambience

Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt)

 

Maximum 1000m (3280.80feet) above sea level for standard operation.

 

After that derate by 3% for every extra 500m (1640.40feet) up to 2500m

 

Altitude, vibration

 

(8202.00feet) (91%).

 

 

 

 

5.9m/s2 or less (conforming to JIS C 0040)

*Temperatures applicable for a short time, e.g. in transit.

(2) Wiring

CAUTION

!Do not fit capacitive equipment such as a power factor correction capacitor, radio noise filter or surge suppressor to the output of the inverter.

!The connection orientation of the output cables U, V, W to the motor will affect the direction of rotation of the motor.

(3)Trial run

CAUTION

!Check all parameters, and ensure that the machine will not be damaged by a sudden start-up.

(4)Operation

CAUTION

!When you have chosen the retry function, stay away from the equipment as it will restart suddenly after an alarm stop.

!The [STOP] key is valid only when the appropriate function setting has been made. Prepare an emergency stop switch separately.

!Make sure that the start signal is off before resetting the inverter alarm. A failure to do so may restart

the motor suddenly.

A - 3

Page 4
Image 4
Mitsumi electronic 55K, FR-F520-0.75K instruction manual Additional instructions