4.2.4 Multi-speed operation (Pr. 4 to Pr. 6, Pr. 24 to Pr.27)

Pr. 4 "multi-speed setting (high speed)" Pr. 5 "multi-speed setting (middle speed)" Pr. 6 "multi-speed setting (low speed)"

Pr. 24 to Pr. 27 "multi-speed setting (speeds 4 to 7)"

Related parameters

Pr. 1 "maximum frequency" Pr. 2 "minimum frequency" Pr. 15 "jog frequency"

Pr. 28 "multi-speed input compensation"

Pr. 29 "acceleration/deceleration pattern"

Pr. 79 "operation mode selection" Pr. 180 to Pr. 186 (input terminal

function selection)

Used to preset the running speeds in parameters and switch between them using terminals.

#Any speed can be selected by switching on-off the contact signal (RH, RM, RL or REX signal).

#By using these functions with jog frequency (Pr. 15), maximum frequency (Pr. 1) and minimum frequency (Pr. 2), up to 10 speeds can be set.

#Valid in the external operation mode or PU/external combined operation mode (Pr. 79 = 3 or 4).

Parameter

Factory Setting

Setting Range

Remarks

Number

 

 

 

4

60Hz

0 to 120Hz

 

5

30Hz

0 to 120Hz

 

6

10Hz

0 to 120Hz

 

24 to 27

9999

0 to 120Hz, 9999

9999: Not selected

Output frequency (Hz)

Speed 1

(high speed)Speed 2

(middle speed) Speed 4

Speed 3 (low speed)

Speed 5

Speed 6

Speed 7

Time

RH

ON

 

ON

ON ON

 

 

 

 

 

 

 

 

 

 

RM

ON

ON

 

ON

ON

 

 

 

 

 

RL

ON

ON

ON

4

 

 

 

 

 

<Setting>

Set the running frequencies in the corresponding parameters.

Each speed (frequency) can be set as desired between 0 and 120Hz during inverter operation.

After the required multi-speed setting parameter has been read, the setting can be changed by pressing the key. (In this case, when you release the key, press the SET key to store the set frequency.

When using the FR-PU04 (option), press the WRITE key.)

Note: 1. The multi-speed settings override the main speeds (across terminals 2-5, 4-5).

2.The multi-speeds can also be set in the PU or external operation mode.

3.For 3-speed setting, if two or three speeds are simultaneously selected, priority is given to the frequency setting of the lower signal.

4.Pr. 24 to Pr. 27 settings have no priority between them.

5.The parameter values can be changed during operation.

6.When input terminal assignment is changed using Pr. 180 to Pr. 186, the other functions may be affected. Check the functions of the corresponding terminals before making setting.