PARAMETERS

 

 

 

 

Minimum

Factory

Refer

Cust-

Func-

Parameter

 

 

Setting

omer

Name

Setting Range

Setting

To

tion

Number

EC

Set-

 

 

Increments

Page:

 

 

 

 

Version

ting

 

 

 

 

 

 

flexiblepoint-5 V/F characteristics

107

V/F4 (fourth frequency voltage)

0 to 1000V

0.1V

0

108

 

 

 

 

 

 

 

 

108

V/F5 (fifth frequency)

0 to 120Hz, 9999

0.01Hz

9999

108

 

 

 

 

 

 

 

 

 

 

 

 

109

V/F5 (fifth frequency voltage)

0 to 1000V

0.1V

0

108

 

 

 

 

 

 

 

 

 

functions

117

Station number

0 to 31

1

0

109

 

119

Stop bit length/data length

 

1

1

109

 

 

118

Communication speed

48, 96, 192

1

192

109

 

 

 

 

0, 1 (data length 8)

 

 

 

 

Communication

 

 

10, 11 (data length 7)

 

 

 

 

120

Parity check presence/absence

0, 1, 2

1

2

109

 

 

 

 

121

Number of communication retries

0 to 10, 9999

1

1

109

 

 

122

Communication check time interval

0, 0.1 to 999.8 s, 9999

0.1 s

0 9999

109

 

 

123

Waiting time setting

0 to 150ms, 9999

1ms

9999

109

 

 

124

CR LF presence/absence selection

0,1,2

1

1

109

 

 

128

PID action selection

10, 11, 20, 21



10

120

 

 

(30, 31 Note 5)

 

 

 

 

 

 

 

 

control

129

PID proportional band

0.1 to 1000%, 9999

0.1%

100%

120

 

130

PID integral time

0.1 to 3600 s, 9999

0.1 s

1 s

120

 

 

 

PID

131

Upper limit

0 to 100%, 9999

0.1%

9999

120

 

132

Lower limit

0 to 100%, 9999

0.1%

9999

120

 

 

133

PID action set point for PU operation

0 to 100%

0.01%

0%

120

 

 

134

PID differential time

0.01 to 10.00 s, 9999

0.01 s

9999

120

 

supplypowerCommercial- over-switchinverter

139

Commercial power supply-inverter

0 to 60.00Hz, 9999

0.01Hz

9999

127

 

 

 

 

135

switch-over sequence output terminal

0, 1

1

0

127

 

 

 

selection

 

 

 

 

 

 

136

MC switch-over interlock time

0 to 100.0 s

0.1 s

1.0 s

127

 

 

137

Start waiting time

0 to 100.0 s

0.1 s

0.5 s

127

 

 

 

Commercial power supply-inverter

 

 

 

 

 

 

138

switch-over selection at alarm

0, 1

1

0

127

 

 

 

occurrence

 

 

 

 

 

 

 

Automatic inverter-commercial power

 

 

 

 

 

 

 

supply switch-over frequency

 

 

 

 

 

 

140

Backlash acceleration stopping

0 to 120Hz

0.01Hz

1.00Hz

79

 

 

frequency (Note 2)

 

 

 

 

 

 

 

 

Backlash

142

Backlash acceleration stopping time

0 to 120Hz

0.01Hz

1.00Hz

79

 

 

141

(Note 2)

0 to 360 s

0.1 s

0.5 s

79

 

 

 

 

 

 

 

 

 

 

Backlash deceleration stopping

 

 

 

 

 

 

 

frequency (Note 2)

 

 

 

 

 

 

143

Backlash deceleration stopping time

0 to 360 s

0.1 s

0.5 s

79

 

 

(Note 2)

 

 

 

 

 

 

 

 

Display

144

Speed setting switch-over

0, 2, 4, 6, 8, 10, 102,

1

4

82

 

 

 

 

104, 106, 108, 110

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

functions

145

Parameter for option (FR-PU04)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Additional

148

Stall prevention operation level at 0V

0 to 150%

0.1%

120%

77

 

input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

149

Stall prevention operation level at 10V

0 to 150%

0.1%

150%

77

 

 

input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 