PARAMETERS

4.2.27Acceleration/deceleration reference current/lift mode starting frequency (Pr. 61 to Pr. 63)

Pr. 61 "Reference I for intelligent mode" Pr. 62 "Ref. I for intelligent mode accel" Pr. 63 "Ref. I for intelligent mode decel"

Related parameter

Pr. 60 "intelligent mode selection"

#Set these parameters to improve performance in the intelligent mode.

Parameter

Factory

Setting Range

Remarks

Number

Setting

 

 

61

9999

0 to 500A, 9999

9999: Referenced from rated inverter

current.

 

 

 

62

9999

0 to 150%, 9999

 

63

9999

0 to 150%, 9999

 

<Setting>

(1) Pr. 61 "Reference I for intelligent mode"

Setting

Reference Current

9999 (factory setting)

Referenced from rated inverter current

0 to 500A

Referenced from setting (rated motor current)

(2) Pr. 62 "Ref. I for intelligent mode accel"

(The reference value differs between the shortest acceleration/deceleration mode and optimum acceleration/deceleration mode.)

The reference current setting can be changed.

Setting

Reference Current

Remarks

9999 (factory setting)

120% (150%) is the limit value.

Shortest acceleration/deceleration mode

100% is the optimum value.

Optimum acceleration/deceleration mode

 

 

The setting of 0 to 150% is the limit value.

Shortest acceleration/deceleration mode

0 to 150%

The setting of 0 to 150% is the optimum

Optimum acceleration/deceleration mode

 

value.

 

 

(3) Pr. 63 "Ref. I for intelligent mode decel "(%)

(The reference value differs between the shortest acceleration/deceleration mode and optimum acceleration/deceleration mode.)

The reference current setting can be changed.

Setting

Reference Current

Remarks

9999 (factory setting)

120% (150%) is the limit value.

Shortest acceleration/deceleration mode

100% is the optimum value.

Optimum acceleration/deceleration mode

 

 

The setting of 0 to 150% is the limit value.

Shortest acceleration/deceleration mode

0 to 150%

The setting of 0 to 150% is the optimum

Optimum acceleration/deceleration mode

 

value.

 

 

Note: Pr. 61 to Pr. 63 are only valid when any of "3" or "4" is selected for Pr. 60.

94

Page 107
Image 107
Mitsumi electronic FR-F520-0.75K, 55K Setting Pr Reference I for intelligent mode, Pr Ref. I for intelligent mode accel