PARAMETERS

How to make a restart after a stop made by the external operation

STOP

key from the PU during

RESET

 

(1)Operation panel (FR-DU04)

1)After completion of deceleration to a stop, switch off the STF or STR signal.

2)Press the MODE key two times* to call the indication. (Note 8)

Note: When Pr. 79 = "3", press the MODE key three times to call the indication.

Then press the key and proceed to step 3).

(*: For monitor screen)

Refer to page 46 for the monitor display provided by pressing the MODE key.

3)Press the SET key.

4)Turn on the STF or STR signal.

(2)Parameter unit (FR-PU04)

1)After completion of deceleration to a stop, switch off the STF or STR signal.

2)Press the EXT key.

3)Switch on the STF or STR signal.

 

Speed

 

 

 

 

 

Time

Operation panel

SET

key

key

 

 

STOP

 

 

RESET

 

STF

ON

 

 

(STR)

OFF

 

 

Stop and restart example for external operation

The other way of making a restart other than the above method is to perform a power-reset or to make a reset with the inverter reset terminal.

Note: 1.

By entering the reset signal (RES) during operation, the inverter shuts off output while it is reset,

 

 

 

the data of the electronic overcurrent protection and regenerative brake duty are reset, and the

 

 

 

motor coasts.

 

4

2.

The PU disconnection detection function judges that the PU is disconnected when it is removed

 

 

 

 

from the inverter for more than 1 second. If the PU had been disconnected before power-on, it is

 

 

 

 

 

 

not judged as an alarm.

 

 

3.

To resume operation, reset the inverter after confirming that the PU is connected securely.

 

 

4.

When PU disconnection detection is set and the PU is then disconnected during PU jog

 

 

 

operation, the motor decelerates to a stop. The motor will not stop if a PU disconnection alarm

 

 

 

occurs.

 

 

5.

The Pr. 75 value can be set any time. Also, if parameter (all) clear is executed, this setting will not

 

 

 

return to the initial value.

 

 

6.

When the motor is stopped by the PU stop function, PS is displayed but an alarm is not output.

 

 

 

When the PU connector is used for RS-485 communication operation, the reset selection and PU

 

 

 

stop selection functions are valid but the PU disconnection detection function is invalid.

 

 

7.

The reset key of the PU is only valid when the protective function is activated, independent of the

 

 

 

Pr. 75 setting.

 

 

 

 

 

 

101

Page 114
Image 114
Mitsumi electronic 55K, FR-F520-0.75K instruction manual Key from the PU during