INSTALLATION AND WIRING

Data examples

By decreasing the carrier frequency, the noise terminal voltage* can be reduced. Use Pr. 72 to set the carrier frequency to a low value (1kHz). Though motor noise increases at a low carrier frequency, selection of Soft-PWM in Pr. 240 will make it unoffending.

Differences between Noise Terminal Voltages

at Different Carrier Frequencies

Conditions

!Motor: 3.7kW (5HP)

!Average terminal voltage 0dB=1V 120dB=1V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(dB)

120

 

 

 

 

 

 

FR-F520-3.7K

 

 

FR-A120E-3.7K fc=14.5kHz

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

 

 

 

fc=0.7kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fc=14.5kHz

 

 

 

 

 

 

 

 

 

 

terminal

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

fc=2.0kHz Soft-PWM(Factory setting)

 

 

 

 

 

 

Noise

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

0.3

0.5

 

 

 

 

1

 

 

3

 

5

 

 

 

 

10

30

 

 

0

 

 

 

 

 

 

 

Noise frequency (MHz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

By decreasing the carrier frequency, noise will be

By using shielded cables as signal cables, induction

about as low as that of our conventional FR-Z200

noise can be reduced greatly (to 1/10 - 1/100).

series.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Induction noise can also be reduced by moving the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

signal cables away from the inverter output cables.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Separation of 30cm (11.81inches) reduces noise to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2-1/3.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

By fitting the FR-BSF01 or BLF on the inverter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

output side, induction noise to the signal cables can

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

be reduced.

 

 

 

Noise Terminal Voltage of Inverter and Example

Noise Induced to Signal Cables by Inverter Output

of Its Reduction by Noise Filters

 

 

 

 

 

 

 

 

Cables

 

 

 

 

 

 

 

 

 

 

 

Conditions

 

 

 

 

 

 

 

 

 

 

 

Conditions

 

 

 

 

 

 

! Motor:3.7kW (5HP)

 

 

100

 

 

 

 

 

 

! Inverter: FR-F520-3.7K

 

 

 

 

 

! Average terminal voltage

0dB=1V

(dB)

 

 

 

 

 

 

! Motor: SF-JR 4P 3.7kW (5HP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120dB=1V

80

 

 

Parallel cable

 

! Output frequency: 30Hz

terminal voltage (dB)

120

 

 

 

 

 

 

 

Induction voltage

 

 

 

 

 

 

! Noise form: Normal mode

 

 

 

FR-Z220-3.7K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Twisted pair cable

 

 

 

100

 

 

 

 

 

 

 

60

 

 

 

 

5cm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inverter

d(cm) Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coaxial cable

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

FR-BLF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminal

 

 

 

 

 

 

 

 

20

 

 

 

 

 

FR-BSF01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

FR-F520-3.7K(fc=0.7kHz)

 

 

 

 

 

 

 

(4T) Measuring instrument

Noise

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

Line-to-line distance, d (cm)

0

 

 

 

 

 

 

 

 

 

10

20

30

40

50

0.1

0.3

0.5

1

3

5

10

30

 

 

 

 

 

 

 

 

 

 

Noise frequency (MHz)

*Noise terminal voltage: Represents the magnitude of noise propagated from the inverter to the power supply.

2

34

Page 45
Image 45
Mitsumi electronic FR-F520-0.75K, 55K Data examples, Noise Terminal Voltage of Inverter and Example, Cables