Parameter List

PARAMETERS

 

 

 

 

 

 

 

Minimum

 

Factory

Refer

Cust-

Func-

Parameter

 

 

 

 

 

Setting

omer

Name

Setting Range

Setting

 

To

tion

Number

 

 

EC

Set-

 

 

 

 

Increments

 

 

Page:

 

 

 

 

 

 

 

 

Version

ting

 

 

 

 

 

 

 

 

 

 

Sub functions

$

240

Soft-PWM setting

0, 1

 

1

 

 

1

98

 

 

 

 

 

 

 

 

 

 

 

 

 

 

$ 244

Cooling fan operation selection

0, 1

 

1

 

 

0

143

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

function

251

Output phase failure protection selection

0, 1

 

1

 

 

1

143

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Additional

252

Override bias

0 to 200%

0.1%

 

 

50%

144

 

 

 

 

 

 

 

 

 

 

 

 

 

 

253

Override gain

0 to 200%

0.1%

 

150%

144

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500

Auxiliary motor operation selection

0 to 3

1

 

 

0

145

 

 

501

Motor switch-over selection

0 to 2

1

 

 

0

145

 

 

502

MC switching interlock time

0 to 100s

0.1s

 

 

 

1s

145

 

 

503

Start waiting time

0 to 100s

0.1s

 

 

 

1s

145

 

5)

504

Auxiliary motor connection-time

0 to 3600s

0.1s/0.01s

 

 

 

1s

145

 

deceleration time

 

 

 

 

(Note

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

505

Auxiliary motor disconnection-time

0 to 3600s, 9999

0.1s/0.01s

 

 

 

1s

145

 

 

 

 

 

 

functions

acceleration time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

506

Output stop detection time

0 to 3600s, 9999

0.1s/0.01s

 

 

9999

145

 

 

 

 

 

 

507

Output stop detection level

0 to 120Hz

0.01Hz

 

 

0Hz

145

 

control

508

Output stop cancel process value level

0 to 100%

0.1%

 

100%

145

 

509

Auxiliary motor 1 starting frequency

0 to 120Hz

0.01Hz

 

 

60Hz

145

 

 

 

 

 

 

 

<50Hz>

 

PID

 

 

 

 

 

 

 

 

 

 

510

Auxiliary motor 2 starting frequency

0 to 120Hz

0.01Hz

 

 

60Hz

145

 

 

 

 

 

Advanced

 

<50Hz>

 

 

 

 

 

 

 

 

 

 

 

511

Auxiliary motor 3 starting frequency

0 to 120Hz

0.01Hz

 

 

60Hz

145

 

 

 

 

 

 

 

<50Hz>

 

 

 

 

 

 

 

 

 

 

 

 

 

512

Auxiliary motor 1 stopping frequency

0 to 120Hz

0.01Hz

 

 

0Hz

145

 

 

513

Auxiliary motor 2 stopping frequency

0 to 120Hz

0.01Hz

 

 

0Hz

145

 

 

514

Auxiliary motor 3 stopping frequency

0 to 120Hz

0.01Hz

 

 

0Hz

145

 

 

515

Auxiliary motor start delay frequency

0 to 3600s

0.1s

 

 

 

5s

145

 

 

516

Auxiliary motor stop delay frequency

0 to 3600s

0.1s

 

 

 

5s

145

 

 

$ 900

FM terminal calibration



 





 

 

 

155

 

functions

$ 901

AM terminal calibration



 





 

 

 

155

 

$ 902

Frequency setting voltage bias

0 to 10V

 

0 to 60Hz

0.01Hz

 

0V

 

0Hz

157

 

 

 

 

 

 

 

$ 903

Frequency setting voltage gain

0 to 10V

 

1 to

0.01Hz

 

5V

 

60Hz

157

 

Calibration

 

120Hz

 

 

50Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 to

 

 

20

 

60Hz

 

 

 

$ 904

Frequency setting current bias

0 to 20mA

 

0 to 60Hz

0.01Hz

 

4

 

0Hz

157

 

 

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

$ 905

Frequency setting current gain

0 to 20mA

 

120Hz

0.01Hz

 

mA

 

50Hz

157

 

 

 

 

 

 

 

 

 

 

 

 

functionAdditional

$ 990

Buzzer control

0, 1

 

1

 

 

1

162

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

991

Parameter for option (FR-PU04)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: 1. The setting depends on the inverter capacity.

2.Can be accessed when Pr. 29 = 3.

3.The half-tone screened parameters allow their settings to be changed during operation if 0 (factory setting) has been set in Pr. 77. (Note that the Pr. 72 and Pr. 240 settings cannot be changed during external operation.)

The parameters which can be changed whilst the inverter is running will also depend upon the setting of Pr. 160 “user group read selection”.

4.The setting depends on the inverter capacity: (0.75K)/(1.5K to 3.7K)/(5.5K, 7.5K)/(11K or more).

5.Setting may be made for the NA and EC versions only.