Mitsumi electronic FR-F520-0.75K, 55K Data definitions, Control codes, Ascii Code Description

Models: FR-F520-0.75K 55K

1 217
Download 217 pages 2.41 Kb
Page 125
Image 125

PARAMETERS

Note: 1. The inverter station numbers may be set between H00 and H1F (stations 0 and 31) in hexadecimal.

2.*3 indicates the control code.

3.*4 indicates the CR or LF code.

When data is transmitted from the computer to the inverter, codes CR (carriage return) and LF (line feed) are automatically set at the end of a data group on some computers. In this case, setting must also be made from the inverter according to the computer.

Also, the presence and absence of the CR and LF codes can be selected using Pr. 124.

4.*5: When Pr. 123 "waiting time setting" 9999, create the communication request data with no "waiting time" in the data format. (The number of characters decreases by 1.)

2)Reply data from inverter to computer during data write

[No data error detected]

 

 

 

 

[Data error detected]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*3

 

Inverter

 

 

 

 

 

*3

Inverter

Error

 

 

 

Format C

 

 

station

*4

 

 

Format D

 

station

*4

 

 

 

ACK

 

 

 

 

NAK

 

 

 

 

 

number

 

 

 

 

 

number

code

 

 

 

 

1

 

2 3

4 Number of

 

1

2 3

4

5 Number of

 

 

 

 

 

 

 

characters

 

 

 

 

 

 

 

characters

3) Reply data from inverter to computer during data read

[No data error detected]

Format E

*3

Inverter

Read data

*3

Sum

*4

 

station

 

STX

ETX

check

 

 

 

number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Data error detected]

Format F

 

1

2

3

4

5

6

7

8

9

 

10

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format E'

 

*3

Inverter

Read

*3

 

Sum

*4

 

 

 

 

 

station

 

 

 

 

 

 

STX

 

data

ETX

check

 

 

 

 

 

 

number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

Number of characters

 

*3

Inverter

Error

*4

 

 

station

 

 

NAK

code

 

 

number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

 

4) Send data from computer to inverter during data read

[No data error detected]

 

 

 

 

[Data error detected]

 

 

 

 

 

 

 

Format G

 

 

*3

 

Inverter

 

 

Format H

 

*3

Inverter

 

 

 

 

 

 

station

*4

 

 

station

*4

 

 

 

 

 

ACK

 

 

 

NAK

 

 

 

 

 

 

 

 

number

 

 

 

 

 

number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

Number of characters

1

2

3

4 Number of characters

(4) Data definitions

 

 

 

 

 

 

 

 

 

 

 

 

 

1) Control codes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal

 

ASCII Code

 

 

 

Description

 

 

 

 

 

 

 

STX

 

 

 

H02

 

Start of Text (Start of data)

 

 

 

 

 

 

 

ETX

 

 

 

H03

 

End of Text (End of data)

 

 

 

 

 

 

 

ENQ

 

 

 

H05

 

Enquiry (Communication request)

 

 

 

 

 

 

 

ACK

 

 

 

H06

 

Acknowledge (No data error detected)

 

 

 

 

 

 

 

LF

 

 

 

H0A

 

Line Feed

 

 

 

 

 

 

 

 

 

 

CR

 

 

 

H0D

 

Carriage Return

 

 

 

 

 

 

 

NAK

 

 

 

H15

 

Negative Acknowledge (Data error detected)

 

 

 

 

 

 

2)Inverter station number

Specify the station number of the inverter which communicates with the computer.

3)Instruction code

Specify the processing request (e.g. operation, monitoring) given by the computer to the inverter. Hence, the inverter can be run and monitored in various ways by specifying the instruction code as appropriate. (Refer to page 195)

4)Data

Indicates the data such as frequency and parameters transferred to and from the inverter. The definitions and ranges of set data are determined in accordance with the instruction codes. (Refer to page 195)

112