Mitsumi electronic 55K, FR-F520-0.75K Minimum Factory Refer Cust Func Parameter Setting

Models: FR-F520-0.75K 55K

1 217
Download 217 pages 2.41 Kb
Page 76
Image 76

PARAMETERS

 

 

 

 

 

Minimum

Factory

Refer

Cust-

Func-

Parameter

 

 

Setting

omer

Name

Setting Range

Setting

To

tion

Number

EC

Set-

 

 

Increments

Page:

 

 

 

 

 

Version

ting

 

 

 

 

 

 

 

Current detection

152

Zero current detection level

0 to 200.0%

0.1%

5.0%

133

 

 

 

 

 

 

 

 

 

153

Zero current detection period

0 to 1 s

0.01 s

0.5 s

133

 

 

 

 

 

 

 

 

 

 

 

 

 

154

Voltage reduction selection during stall

0, 1

1

1

77

 

functions

prevention operation

 

 

 

 

 

 

 

 

155

RT signal activated condition

0, 10

1

0

134

 

 

 

 

156

Stall prevention operation selection

0 to 31, 100, 101

1

0

134

 

Sub

157

OL signal waiting time

0 to 25 s, 9999

0.1 s

0

136

 

158

AM terminal function selection

1 to 3, 5 to 6, 8,

1

1

86

 

 

 

 

10 to 14, 17, 21

 

 

 

 

 

 

 

 

 

Additional function

$

160

User group read selection

0, 1, 10, 11, 9999

1

9999

137

 

 

 

 

 

 

 

 

 

 

 

 

restartAutomatic instantaneousafter failurepower

162

Automatic restart after instantaneous

0, 1

1

0

89

 

power failure selection

 

 

 

 

 

 

 

 

 

 

 

 

163

First cushion time for restart

0 to 20 s

0.1 s

0 s

89

 

 

 

 

 

 

 

 

 

 

164

First cushion voltage for restart

0 to 100%

0.1%

0%

89

 

 

 

 

 

 

 

 

 

 

165

Restart stall prevention operation level

0 to 150%

0.1%

120%

89

 

Sub functions

169

 

 

 

 

 

 

 

168

 

 

 

 

 

 

 

 

 

Parameters set by the manufacturer. Do not set.

 

 

 

 

 

 

 

 

 

 

 

 

Initial monitor

170

Watt-hour meter clear

0



0

138

 

 

 

 

 

 

 

 

171

Actual operation hour meter clear

0



0

138

 

 

 

 

 

 

 

 

 

 

functions

173

User group 1 registration

0 to 999

1

0

137

 

 

 

 

 

 

 

 

 

 

 

 

174

User group 1 deletion

0 to 999, 9999

1

0

137

 

 

 

 

 

 

 

 

 

User

175

User group 2 registration

0 to 999

1

0

137

 

 

 

 

 

 

 

 

176

User group 2 deletion

0 to 999, 9999

1

0

137

 

 

$ 180

RL terminal function selection

 

1

0

138

 

 

$ 181

RM terminal function selection

 

1

1

138

 

functions

$ 182

RH terminal function selection

0 to 7, 10 to 14, 16,

1

2

138

 

$ 183

RT terminal function selection

9999

1

3

138

 

 

 

 

$ 184

AU terminal function selection

(24 Note 5)

1

4

138

 

assignment

$ 185

JOG terminal function selection

 

1

5

138

 

$ 186

CS terminal function selection

 

1

6

138

 

 

 

 

 

$ 190

RUN terminal function selection

0 to 5, 8, 10, 11,

1

0

140

 

Terminal

$ 191

SU terminal function selection

13 to 19, 25, 26,

1

1

140

 

$ 193

OL terminal function selection

125, 126, 198, 199,

1

3

140

 

 

$ 192

IPF terminal function selection

98 to 105, 108,

1

2

140

 

 

 

 

 

110, 111, 113 to 116,

 

 

 

 

 

 

 

 

 

 

 

 

 

$ 194

FU terminal function selection

9999

1

4

140

 

 

$ 195

A, B, C terminal function selection

(40 to 48 Note 5)

1

99

140

 

 

 

 

 

 

 

 

 

 

Additi- onal function

199

User's initial value setting

0 to 999, 9999

1

0

142

 

 

 

 

 

 

 

 

 

 

 

 

Parameter List

4

63

Page 76