PROTECTIVE FUNCTIONS

 

 

 

 

 

 

 

 

 

 

 

Operation Panel

 

E.P24

 

 

FR-PU04

 

E. P24

 

 

Indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

24VDC power output short circuit

 

 

 

 

When the 24VDC power output from the PC terminal is shorted, this function

 

 

Description

shuts off the power output. At this time, all external contact inputs switch off.

 

 

The inverter cannot be reset by entering the RES signal. To reset, use the

 

 

 

 

 

 

operation panel or switch power off, then on again.

 

 

 

Check point

Check for a short circuit in the PC terminal output.

 

 

 

Corrective action

Remedy the short circuit portion.

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Panel

E.CTE

 

 

FR-PU04

 



 

 

Indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

Operation panel power supply short circuit

 

 

 

 

When the operation panel power supply (P5S of the PU connector) is shorted,

 

 

 

this function shuts off the power supply output. At this time, the operation panel

 

 

Description

(parameter unit) cannot be used and RS-485 communication from the PU

 

 

 

connector cannot be made. To reset, enter the RES signal or switch power off,

 

 

 

then on again.

 

 

 

 

 

Check point

Check for a short circuit in the PU connector cable.

 

 

 

Corrective action

Check the PU and cable.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Panel

 

E.LF

 

 

FR-PU04

 



 

 

Indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

Output phase failure protection

 

 

 

Description

This function stops the inverter output if one of the three phases (U, V, W) on

 

 

the inverter's output side (load side) results in open phase.

 

 

 

 

 

 

Check the wiring (Check the motor for a fault.)

 

 

 

Check point

Check that the capacity of the used motor is not smaller than the inverter

 

 

 

 

capacity.

 

 

 

 

 

Corrective action

Wire the cables properly.

 

 

 

 

 

Check the setting of Pr. 251 "output phase failure protection selection".

 

 

 

 