OPERATION/CONTROL

3.4.4Combined operation mode

(Operation using the external input signals and PU)

When entering the start signal from outside the inverter and setting the running frequency from the PU (Pr. 79 = 3)

The external frequency setting signals and the PU's FWD, REV and STOP keys are not accepted. (Note)

Step

Description

Image

Power-on

Switch power on.

ON

1

 

Operation mode selection

 

 

 

 

 

Set "3" in Pr. 79 "operation mode selection".

 

 

 

 

 

The combined operation mode is selected and the operation status indication "EXT"

 

 

 

 

2

and "PU" are lit.

 

Flicker

 

 

 

Start

Forward

 

 

 

 

Turn on the start switch (STF or STR).

 

 

 

 

rotation

 

 

 

 

 

Reverse

 

 

 

 

 

 

 

 

Note: The motor does not start if both the forward and reverse rotation switches are

 

rotation

 

 

3

 

 

 

 

turned on. If both switches are turned on during operation, the motor

 

FR-DU04

CONTROL PANEL

 

decelerates (when Pr. 250 = "9999") to a stop.

 

 

 

Hz

 

 

 

 

V

 

 

 

 

 

A

 

 

ON

MON

EXT

PU

 

 

 

 

REV

FWD

4

Running frequency setting

Using the parameter unit, set the running frequency to 60Hz. The operation command indication "REV" or "FWD" flickers.

Select the frequency setting mode and make step setting.

Note: Step setting is the way of changing the frequency consecutively by pressing

the

key.

<Step setting>

Hold down the key to change the frequency.

Stop

 

 

 

 

 

Turn off the start switch (STF or STR).

 

 

 

 

 

The motor stops running.

FR-DU04

CONTROL PANEL

 

 

 

 

 

Hz

5

 

 

 

A

 

 

 

V

 

MON

EXT

 

PU

 

 

REV

 

FWD

 

 

 

 

 

 

 

Note: The stop key is made valid when the Pr. 75 "PU stop selection" value is set to any of 14 to 17.

59

Page 71
Image 71
Mitsumi electronic FR-F520-0.75K, 55K instruction manual Step Description, Start, Decelerates when Pr = 9999 to a stop