OPERATION/CONTROL
47
3.2.3 Monitoring

Operation command indications in the monitoring

EXT is lit to indicate external operation.

PU is lit to indicate PU operation.

Both EXT and PU are lit to indicate PU/external combined operation mode.

The monitor display can also be changed during operation.

MODE
SET SET SET
SET
SET
SET
*1
SET
*1
SET
*1

*2

To 3.2.4 Frequency setting (Note 3)

#Frequency monitor #Current monitor #Voltage monitor #Alarm monitor

Alarm

present

Alarm absent

FR-DU04 CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04 CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04 CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04 CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD

Note: 1. Hold down the SET key marked *1 for more than 1.5 seconds to change the current monitor to the

power-on monitor.

2. Hold down the SET key marked *2 for more than 1.5 seconds to display four errors including the

most recent one.

3. Shifts to the parameter setting mode when in the external operation m ode.

3.2.4 Frequency setting

Used to set the running frequency in the PU operation mode.

MODE
SET
MODE

To 3.2.5 Parameter setting method

#Set frequency write

#Set frequency change

Press to change the set frequency.

To frequency monitor

FR-DU04 CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04 CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04 CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
FR-DU04 CONTROL PANEL
Hz
MON EXT PU
A
V
REV FWD
Flicker

#Frequency setting mode