PARAMETERS

 

 

 

 

 

 

Setting

Signal

 

 

Related

Positive

Negative

Function

Operation

Name

parameter

logic

logic

 

 

 

 

 

 

17



MC1

Commercial power supply-

 

 

inverter switch-over MC1

 

 

 

 

 

 

 

18



MC2

Commercial power supply-

Refer to Pr. 135 to Pr.139 (commercial power

Pr. 135 to

inverter switch-over MC2

supply-inverter switch-over).

Pr. 139

 

 

 

19



MC3

Commercial power supply-

 

 

inverter switch-over MC3

 

 

 

 

 

 

 

25

125

FAN

Fan fault output

Output only when a fan fault occurs.

Pr. 244

 

 

 

 

Output when the heat sink temperature reaches

 

26

126

FIN

Fin overheat pre-alarm

about 85% of the fin overheat protection



 

 

 

 

temperature.

 

40



SLEEP

Output at stop

 

 

41



R01

Commercial power supply side

 

 

motor 1 connection R01

 

 

 

 

 

 

 

42



R02

Commercial power supply side

 

 

motor 2 connection R02

 

 

 

 

 

 

 

43



R03

Commercial power supply side

 

 

motor 3 connection R03

 

 

 

 

 

Refer to Pr. 500 to Pr. 516 (advanced PID

 

44



R04

Commercial power supply side

 

control). (Page 145)

Pr. 500 to

 

 

 

motor 4 connection R04

(Setting may be made for the NA and EC versions

Pr. 516

 



 

Inverter side motor 1

45

RI01

only.)

 

connection RI01

 

 

 

 

 

 

46



RI02

Inverter side motor 2

 

 

connection RI02

 

 

 

 

 

 

 

47



RI03

Inverter side motor 3

 

 

connection RI03

 

 

 

 

 

 

 

48



RI04

Inverter side motor 4

 

 

connection RI04

 

 

 

 

 

 

 

98

198

LF

Minor fault output

Output when a light fault (fan fault or

Pr. 121, Pr. 244

communication error alarm) occurs.

 

 

 

 

 

99

199

ABC

Alarm output

Output when the inverter's protective function is



activated to stop the output (major fault).

 

 

 

 

 

9999



No function





0 to 99:

Positive logic

 

 

 

100 to 199: Negative logic

 

 

 

Note: 1. When the frequency setting is varied with the analog signal or the key of the operation panel, note that the output of the SU (up-to-frequency) signal may alternate between ON and OFF due to that varying speed and the timing of the varying speed dependent on the acceleration/deceleration time setting.

(Such alternation will not take place when the acceleration/deceleration time setting is "0 s".)

2.The same function may be set to more than one terminal.

3.When the function is activated, the terminal conducts with the settings of 0 to 99 and does not conduct with the settings of 100 to 199.

4.Pr. 190 to Pr. 195 do not function if the values set are other than the above.

5.When Pr. 76 = 1 or 3, the output signals of the SU, IPF, OL and FU output terminals conform to Pr. 76. When an inverter alarm occurs, the signal outputs are switched over to alarm code outputs.

6.The output assignment of the RUN terminal and alarm output relay conforms to the above setting independently of Pr. 76.