Mitsumi electronic FR-F520-0.75K, 55K instruction manual Input terminal function selection Pr to Pr

Models: FR-F520-0.75K 55K

1 217
Download 217 pages 2.41 Kb
Page 151
Image 151

PARAMETERS

Note: 1. Pr. 77, Pr. 160 and Pr. 991 values can always be read independently of the user group setting.

2.When Pr. 173 or Pr. 174 is read, the number of parameters registered to user group 1 appears. When Pr. 175 or Pr. 176 is read, the number of parameters registered to user group 2 appears.

3."0" set in the second digit of the 2-digit Pr. 160 setting is not displayed. However, it is displayed when "0" is set in the first digit only.

4.When "9999" is set in Pr. 174 or Pr. 176, the parameters registered to the corresponding user group is batch-deleted.

Pr. 162 to Pr. 165 % Refer to Pr. 57.

4.2.47Watt-hour meter clear/actual operation hour meter clear (Pr. 170, Pr. 171)

Pr. 170 "watt-hour meter clear"

Pr. 171 "actual operation hour meter clear"

Related parameter

Pr. 52 "DU/PU main display data selection"

You can clear the watt-hour value and actual operation hour monitoring function.

Parameter

Factory

Setting Range

Number

Setting

 

170

0

0

171

0

0

<Setting>

Write "0" in the parameters to clear the watt-hour value and actual operation hour.

REMARKS

The watt-hour value is monitored at the Pr. 52 setting of "25", and the actual operation hour at the Pr. 52 setting of "23".

Pr. 173 to Pr. 176 % Refer to Pr. 160.

4.2.48 Input terminal function selection (Pr. 180 to Pr. 186)

Pr. 180 "RL terminal function selection"

Pr. 181 "RM terminal function selection"

Pr. 182 "RH terminal function selection"

Pr. 183 "RT terminal function selection"

Pr. 184 "AU terminal function selection"

Pr. 185 "JOG terminal function selection"

Pr. 186 "CS terminal function selection"

Use these parameters to select/change the input terminal functions.

Parameter

Terminal

Factory

Factory-Set Terminal Function

Setting Range

Number

Symbol

Setting

 

 

180

RL

0

Low-speed operation command (RL)

 

181

RM

1

Middle-speed operation command (RM)

0 to 7, 10 to 14,

182

RH

2

High-speed operation command (RH)

16, 17, 9999

183

RT

3

Second function selection (RT)

(24 may also be set

184

AU

4

Current input selection (AU)

for the NA and EC

185

JOG

5

Jog operation selection (JOG)

versions only.)

186

CS

6

Automatic restart after instantaneous

 

power failure selection (CS)

 

 

 

 

 

138

Page 151
Image 151
Mitsumi electronic FR-F520-0.75K, 55K Input terminal function selection Pr to Pr, Jog operation selection JOG