OPERATION/CONTROL

3.4.3PU operation mode

(Operation using the operation panel (FR-DU04))

(1) Operation at 60Hz

While the motor is running, repeat the following steps 2 and 3 to vary the speed:

Step

 

 

Description

Image

 

 

 

Power-on Operation mode check

 

 

 

 

 

 

Switch power on and make sure that the operation command indication "PU" is lit.

ON

 

 

 

 

 

(If it is not lit, press the MODE key to choose the operation mode and press the

 

 

 

 

 

1

 

key to switch to PU operation. For operation mode changing, refer to page

 

 

FR-DU04

CONTROL PANEL

 

49.)

 

 

 

 

 

 

 

 

 

 

 

 

 

MON

EXT

PU

 

 

 

 

 

 

 

REV

FWD

 

Running frequency setting

 

 

 

 

 

 

Set the running frequency to 60Hz.

(or)

 

 

 

 

 

First, press the MODE key to select the frequency setting mode. Then, press the

 

 

 

 

 

 

 

 

 

 

2

 

key to change the setting, and press the SET key to write the frequency.

 

 

FR-DU04

CONTROL PANEL

 

 

 

 

 

 

 

 

Hz

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

MON

EXT

PU

 

 

 

 

 

 

 

REV

FWD

 

Start

 

 

 

 

 

 

 

 

Press the

FWD or REV

key.

FWD (or) REV

 

 

 

 

 

 

 

 

 

 

 

 

 

The motor starts running. The monitoring mode is automatically selected and the

 

 

 

 

 

3

output frequency is displayed.

 

 

FR-DU04

CONTROL PANEL

 

 

 

 

 

 

 

 

 

 

 

 

 

Hz

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

MON

EXT

PU

 

 

 

 

 

 

 

REV

FWD

 

Stop

 

 

 

 

 

 

 

 

Press the

STOP

key.

 

 

 

 

 

 

RESET

 

 

 

 

 

 

The motor is decelerated to a stop.

FR-DU04

CONTROL PANEL

 

 

 

 

 

 

 

 

Hz

 

 

4

 

 

 

 

 

A

 

 

 

 

 

 

 

V

 

 

 

 

 

 

MON

EXT

PU

 

 

 

 

 

 

 

REV

FWD

 

 

(2) PU jog operation

3

Hold down the FWD or REV key to perform operation, and release it to stop.

1)Set Pr. 15 "jog frequency" and Pr. 16 "jog acceleration/deceleration time".

2)Select the PU jog operation. (Press the MODE key to choose the operation mode and press the key to switch to PU JOG operation.)

3)Hold down the FWD or REV key to perform operation.

(If the motor remains stopped, check Pr. 13 "starting frequency". The motor will not start if its setting is lower than the starting frequency.)