OPTIONS

7.1.2Inboard dedicated options

Inboard options

 

Name

Type

 

Function

 

 

 

 

 

 

 

 

Input interface used to set the inverter frequency accurately using external 3-digit BCD or

12-bit digital input

FR-A5AX

 

12-bit binary-coded digital signals.

 

 

 

Gains and offsets can also be adjusted.

Digital output

 

Among standard output signals of the inverter, this option outputs any 7 selected signals

 

 

from open collector output terminals.

 

 

 

 

Extension analog

FR-A5AY

Outputs extra 16 signals which can be monitored on the FM and AM terminals such as

 

 

output frequency, output voltage and output current, etc.

output

 

 

 

20mADC or 5V(10V)DC meter can be connected.

 

 

 

Relay output

FR-A5AR

Among 26 standard output signals of the inverter, this option outputs any 3 selected

 

signals from relay contact output terminals.

 

 

 

 

Auxiliary Control

FR-A5AC

Eight 120VAC inputs which implement the input terminal functions of the inverter.

(Note2)

Two relay outputs which are selected from among standard outputs.

 

Analog input-output

 

One isolated 4-20mA input which can set the frequency command to the inverter.

function

FR-A5AN

Two Isolated 4-20mA outputs which can be connected to an analog meter or other

(Note2)

 

 

compatible device.

 

 

 

Operation/monitoring/parameter change of the inverter can be performed under the control

 

Computer link

 

 

of a user program from a computer, e.g. personal computer or FA controller, connected by

 

 

FR-A5NR

 

a communication cable.

Communication

Relay output

 

Any one output signal can be selected from among the standard output signals of the

 

 

inverter and output as a relay contact (contactor) signal.

 

 

 

 

 

 

 

 

Profibus DP

FR-A5NP

Operation/monitoring/parameter change of the inverter can be performed from a computer

 

 

or PLC.

 

 

 

 

 

DeviceNetTM

FR-A5ND

Operation/monitoring/parameter change of the inverter can be performed from a computer

 

 

or PLC.

 

 

 

 

 

CC-Link (Note 3)

FR-A5NC

Operation/monitoring/parameter change of the inverter can be performed from a PLC.

 

Modbus Plus

FR-A5NM

Operation/monitoring/parameter change of the inverter can be performed from a computer

 

 

or PLC.

 

 

 

 

Note: 1. Three inboard options may be mounted at the same time (the number of the same options mountable is only one, and only one of the communication options may be mounted.)

2.NA version only.

3.CC-Link stands for Control & Communication Link.

194

Page 210
Image 210
Mitsumi electronic 55K, FR-F520-0.75K instruction manual Inboard dedicated options, Name Type Function