4.2.35 Parameter write inhibit selection (Pr. 77)

Pr. 77 "parameter write disable selection"

Related parameters

Pr. 79 "operation mode selection"

You can select between write-enable and disable for parameters. This function is used to prevent parameter values from being rewritten by accident.

Parameter

Factory

Setting Range

Number

Setting

 

77

0

0, 1, 2

<Setting>

Pr. 77 Setting

Function

0Write enabled during a stop only.

Parameter values may only be written during a stop in the PU operation mode. (Note 1)

1Write disabled.

Values of Pr. 22, Pr. 75, Pr. 77 and Pr. 79 "operation mode selection" can be written.

2Write enabled even during operation.

Note: 1. The values of the parameters half-tone screened in "4.1.1 Parameter list" can be set at any time. (Pr. 72 and Pr. 240 values cannot be set during external operation.)

2.If Pr. 77 = "2", the values of the following parameters cannot be written during operation. Stop operation when changing their parameter settings.

Parameter

Name

Parameter

Name

Number

Number

 

 

 

Stall prevention operation level

 

Commercial power supply-inverter

23

135

switch-over sequence output

compensation factor at double speed

 

 

terminal selection

 

 

 

48

Second stall prevention operation

136

MC switch-over interlock time

current

 

 

 

49

Second stall prevention operation

137

Start waiting time

frequency

 

 

 

 

 

 

Commercial power supply-inverter

60

Intelligent mode selection

138

switch-over selection at alarm

 

 

 

occurrence

61

Reference current

139

Automatic inverter-commercial

power supply switch-over frequency

 

 

 

66

Stall prevention operation reduction

180

RL terminal function selection

starting frequency

 

 

 

71

Applied motor

181

RM terminal function selection

79

Operation mode selection

182

RH terminal function selection

100

V/F1 (first frequency)

183

RT terminal function selection

101

V/F1 (first frequency voltage)

184

AU terminal function selection

102

V/F2 (second frequency)

185

JOG terminal function selection

103

V/F2 (second frequency voltage)

186

CS terminal function selection

104

V/F3 (third frequency)

190

RUN terminal function selection

105

V/F3 (third frequency voltage)

191

SU terminal function selection

106

V/F4 (fourth frequency)

192

IPF terminal function selection

107

V/F4 (fourth frequency voltage)

193

OL terminal function selection

108

V/F5 (fifth frequency)

194

FU terminal function selection

109

V/F5 (fifth frequency voltage)

195

A, B, C terminal function selection

3.By setting "1" in Pr. 77, the following clear operations can be inhibited:

Parameter clear

All clear

User clear

4

103

Page 116
Image 116
Mitsumi electronic 55K Parameter write inhibit selection Pr, Pr parameter write disable selection, Parameter Name