Mitsumi electronic FR-F520-0.75K Override bias/gain Pr , Pr, Pr override bias Pr override gain

Models: FR-F520-0.75K 55K

1 217
Download 217 pages 2.41 Kb
Page 157
Image 157

PARAMETERS

4.2.53 Override bias/gain (Pr. 252, Pr. 253)

Pr. 252 "override bias"

Pr. 253 "override gain"

Related parameter

Pr. 73 "0-5V/0-10V selection"

When you have selected override in Pr. 73 "0 to 5V, 0 to 10V selection", you can increase the override range of 50%-150% (to 0%-200%) and make setting as desired.

Parameter Number

Setting Range

Minimum Setting

Factory Setting

Increments

 

 

 

252

0 to 200%

0.1%

50%

253

0 to 200%

0.1%

150%

 

 

200

 

 

 

(%)

150

 

 

 

 

 

 

 

Override

100

 

Factory setting (50% to 150%)

Pr.253

 

 

 

 

 

 

 

 

 

 

 

50

 

 

 

 

0

 

 

 

 

0V

2.5V

5V

 

 

 

(5V)

(10V)

 

 

 

Voltage across terminals 2-5

144

Page 157
Image 157
Mitsumi electronic FR-F520-0.75K, 55K Override bias/gain Pr , Pr, Pr override bias Pr override gain, 150%