Mitsumi electronic 55K, FR-F520-0.75K Alarm history clear, Parameter clear, All clear, User clear

Models: FR-F520-0.75K 55K

1 217
Download 217 pages 2.41 Kb
Page 62
Image 62

OPERATION/CONTROL

(2) Alarm history clear

Clears all alarm history.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flicker

 

 

 

 

FR-DU04

CONTROL PANEL

 

FR-DU04

CONTROL PANEL

 

FR-DU04

CONTROL PANEL

 

FR-DU04

CONTROL PANEL

 

 

 

Hz

SET

 

 

Hz

 

 

 

 

Hz

SET

 

 

Hz

 

 

 

A

 

 

A

 

 

 

 

A

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

V

 

 

 

 

V

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

MON

EXT

 

PU

 

MON

EXT

 

PU

 

MON

EXT

 

PU

 

MON

EXT

 

PU

 

REV

 

FWD

 

 

 

REV

 

FWD

 

 

 

REV

 

FWD

 

 

 

REV

 

FWD

 

SET Cancel

(3) Parameter clear

Initialises the parameter values to the factory settings. The calibration values are not initialized. (Parameter values are not cleared by setting "1" in Pr. 77 "parameter write disable selection".)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flicker

 

 

 

 

FR-DU04

CONTROL PANEL

 

FR-DU04

CONTROL PANEL

 

FR-DU04

CONTROL PANEL

 

FR-DU04

CONTROL PANEL

 

 

 

Hz

SET

 

 

Hz

 

 

 

 

Hz

SET

 

 

Hz

 

 

 

A

 

 

A

 

 

 

 

A

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

V

 

 

 

 

V

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

MON

EXT

 

PU

 

MON

EXT

 

PU

 

MON

EXT

 

PU

 

MON

EXT

 

PU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REV

 

FWD

 

 

 

REV

 

FWD

 

 

 

REV

 

FWD

 

 

 

REV

 

FWD

 

SET Cancel

REMARKS

The Pr. 75, Pr. 180 to Pr. 186, Pr. 190 to Pr. 195, and Pr. 900 to Pr. 905 values are not initialized.

(4) All clear

Initialises the parameter values and calibration values to the factory settings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flicker

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FR-DU04

CONTROL PANEL

 

FR-DU04

CONTROL PANEL

 

FR-DU04

CONTROL PANEL

 

FR-DU04

CONTROL PANEL

 

 

 

Hz

SET

 

 

Hz

 

 

 

 

Hz

SET

 

 

Hz

 

 

 

A

 

 

A

 

 

 

 

A

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

V

 

 

 

 

V

 

 

 

 

V

MON

EXT

 

PU

 

MON

EXT

 

PU

 

MON

EXT

 

PU

 

MON

EXT

 

PU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REV

 

FWD

 

 

 

REV

 

FWD

 

 

 

REV

 

FWD

 

 

 

REV

 

FWD

 

SET Cancel

REMARKS

The Pr. 75 value is not initialized.

(5) User clear

Initialises the user-set parameters.

The other parameters are initialized to the factory settings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flicker

 

 

 

 

FR-DU04

CONTROL PANEL

 

FR-DU04

CONTROL PANEL

 

FR-DU04

CONTROL PANEL

 

FR-DU04

CONTROL PANEL

 

 

 

Hz

SET

 

 

Hz

 

 

 

 

Hz

SET

 

 

Hz

 

 

 

A

 

 

A

 

 

 

 

A

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

V

 

 

 

 

V

 

 

 

 

V

MON

EXT

 

PU

 

MON

EXT

 

PU

 

MON

EXT

 

PU

 

MON

EXT

 

PU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REV

 

FWD

 

 

 

REV

 

FWD

 

 

 

REV

 

FWD

 

 

 

REV

 

FWD

 

SET Cancel

REMARKS

The Pr. 75, Pr. 180 to Pr. 186, and Pr. 190 to Pr. 195 values are not initialized.

50

Page 62
Image 62
Mitsumi electronic 55K, FR-F520-0.75K instruction manual Alarm history clear, Parameter clear, All clear, User clear