Mitsumi electronic 55K Voltage input Pr, Pr 0-5V/0-10V selection, Related parameters, To 5, 10 to

Models: FR-F520-0.75K 55K

1 217
Download 217 pages 2.41 Kb
Page 112
Image 112

PARAMETERS

4.2.31 Voltage input (Pr. 73)

Pr. 73 "0-5V/0-10V selection"

Related parameters

Pr. 22 "stall prevention operation level"

Pr. 903 "frequency setting voltage gain"

Pr. 905 "frequency setting current gain"

You can select the analog input terminal specifications, the override function and the function to switch between forward and reverse rotation depending on the input signal polarity.

Parameter

Factory

Setting Range

Number

Setting

 

73

1

0 to 5, 10 to 15

<Setting>

Pr. 73

Terminal AU

Terminal 2

Terminal 1

Terminal 4 Input,

Override Function

Polarity

 

 

Setting

Signal

Input Voltage

Input Voltage

4 to 20mA

Reversible

 

 

 

 

 

0

 

0 to 10V

0 to ± 10V

 

 

 

 

 

1

 

0 to 5V

0 to ± 10V

 

 

 

 

2

 

0 to 10V

0 to ± 5V

 

No

 

 

 

 

 

 

 

3

 

0 to 5V

0 to ± 5V

 

 

(Note 3)

 

 

4

 

0 to 10V

0 to ± 10V

 

$

 

 

 

5

OFF

0 to 5V

0 to ± 5V

Invalid

 

 

 

 

 

 

 

10

(No)

0 to 10V

0 to ± 10V

 

 

 

 

 

 

 

 

 

11

 

0 to 5V

0 to ± 10V

 

 

 

 

12

 

0 to 10V

0 to ± 5V

 

Valid

 

 

 

 

 

 

 

13

 

0 to 5V

0 to ± 5V

 

 

 

 

 

 

 

 

 

 

14

 

0 to 10V

0 to ± 10V

 

$

 

 

 

15

 

0 to 5V

0 to ± 5V

 

 

 

 

 

 

 

 

 

 

0

 

 

0 to ± 10V

 

 

 

 

 

1

 

Invalid

0 to ± 10V

 

 

 

 

2

 

0 to ± 5V

 

No

 

 

 

 

 

 

 

 

3

 

 

0 to ± 5V

 

 

(Note 3)

 

 

4

 

0 to 10V

Invalid

 

$

 

 

 

5

ON

0 to 5V

Yes

 

 

 

 

 

 

 

 

10

(Yes)

 

0 to ± 10V

 

 

 

 

11

 

Invalid

0 to ± 10V

 

 

 

 

12

 

0 to ± 5V

 

Valid

 

 

 

 

 

 

 

 

13

 

 

0 to ± 5V

 

 

 

4

 

 

 

 

 

 

14

 

0 to 10V

Invalid

 

$

 

 

15

 

0 to 5V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: 1. The value of terminal 1 (frequency setting auxiliary input) is added to the main speed setting signal of terminal 2 or 4.

2.When override has been selected, terminal 1 or 4 is for the main speed setting and terminal 2 is for the override signal (50 to 150% at 0-5V or 0-10V). (If the main speed of terminal 1 or 4 is not input, compensation made by terminal 2 is made invalid.)

3.Indicates that a negative-polarity frequency command signal is not accepted.

4.To change the maximum output frequency at the input of the maximum frequency command voltage (current), use the frequency setting voltage (current) gain, Pr. 903 (Pr. 905). At this time, the command voltage (current) need not be input. Also, the acceleration/deceleration time, which is a slope up/down to the acceleration/deceleration reference frequency, is not affected by the change in Pr. 73 setting.

5.When the Pr. 22 setting is "9999", the value of terminal 1 is for the stall prevention operation level setting.

6.indicates the main speed setting.

99

Page 112
Image 112
Mitsumi electronic 55K, FR-F520-0.75K Voltage input Pr, Pr 0-5V/0-10V selection, Related parameters, To 5, 10 to