Simple mode parameter

 

 

OPERATION/CONTROL

 

 

 

Parameter

Name

Application

Number

 

 

60

Intelligent mode selection

Used to cause the inverter to automatically set the appropriate parameters and

perform operation.

 

 

65

Retry selection

Used to select the alarm whose occurrence will cause the inverter to reset and

retry automatically.

 

 

66

Stall prevention operation reduction

 

starting frequency

 

 

 

67

Number of retries at alarm

Used to set the number of retries to be made when an alarm occurs.

occurrence

 

 

68

Retry waiting time

Used to set the number of retries and the waiting time.

69

Retry count display erasure

 

71

Applied motor

Used to set the thermal characteristic of the electronic overcurrent protection

according to the motor used.

 

 

72

PWM frequency selection

Used to change the motor tone.

73

0-5V/0-10V selection

When using the voltage-input signal to perform operation, set the specifications of

the frequency setting signal input to across terminals 2-5.

 

 

74

Filter time constant

Used to set the input section built-in filter constant of an external voltage or

current frequency setting signal.

 

 

75

Reset selection/disconnected PU

Used to choose the reset selection, disconnected PU detection and PU stop

detection/PU stop selection

selection functions.

 

76

Alarm code output selection

Used to output a 4-bit digital signal from the open collector output terminals as the

definition of an alarm that has occurred.

 

 

77

Parameter write disable selection

Used to enable or disable the write of various parameters to prevent the

parameters from being rewritten by accidental operation.

 

 

78

Reverse rotation prevention selection

Used to prevent reverse operation trouble due to the false input of the start signal.

79

Operation mode selection

Use to choose the operation mode of the inverter.

160

User group read selection

Used to read the values of the basic parameters or all parameters.

180

RL terminal function selection

 

181

RM terminal function selection

 

182

RH terminal function selection

 

183

RT terminal function selection

Used to choose and assign the functions of the input terminals.

184

AU terminal function selection

 

185

JOG terminal function selection

 

186

CS terminal function selection

 

190

RUN terminal function selection

 

191

SU terminal function selection

 

192

IPF terminal function selection

Used to choose and assign the functions of the output terminals.

193

OL terminal function selection

 

194

FU terminal function selection

 

195

A, B, C terminal function selection

 

240

Soft-PWM setting

Used to change the motor tone.

244

Cooling fan operation selection

Used to control the operation of the cooling fan incorporated in the inverter.

900

FM terminal calibration

Used to calibrate the meters connected to terminals FM-SD and AM-5.

901

AM terminal calibration

 

902

Frequency setting voltage bias

 

903

Frequency setting voltage gain

Used to set the magnitude (slope) of the output frequency as desired relative to

904

Frequency setting current bias

the frequency setting signal (0 to 5V, 0 to 10V or 4 to 20mA DC).

905

Frequency setting current gain

 

990

Buzzer control

Used to produce or mute the operational sound generated when you press the

keys of the operation panel and parameter unit.

 

 

53