PARAMETERS

4.2.17 Speed display (Pr. 37, Pr. 144)

Pr. 37 "speed display"

Pr. 144 "speed setting switch-over"

Related parameters

Pr. 52 "DU/PU main display data selection"

Pr. 53 "PU level display data selection"

The units of the running speed monitor display of the PU (FR-DU04/FR-PU04), the running speed setting in the PU operation mode, and the parameter setting used for frequency setting can be changed from the frequency to the motor speed or machine speed.

Parameter

Factory

Setting Range

Remarks

Number

Setting

 

 

37

0

0, 1 to 9998

0: Frequency setting added

144

4

0, 2, 4, 6, 8, 10, 102,

 

104, 106, 108, 110

 

 

 

 

<Setting>

To display the machine speed, set in Pr. 37 the machine speed for 60Hz operation.

To display the motor speed, set the number of motor poles (2, 4, 6, 8, 10) or the number of motor poles plus 100 (102, 104, 106, 108, 110) in Pr. 144.

When values have been set in both Pr. 37 and Pr. 144, priority is as follows:

Pr. 144 = 102 to 110 > Pr. 37 = 1 to 9998 > Pr. 144 = 2 to 10

Hence, the half-tone screened settings in the following list become valid.

When the running speed monitoring has been selected, the parameter setting unit and the running speed setting unit in the PU operation mode depend on the combination of the Pr. 37 and Pr. 144 settings as indicated below:

Running Speed

Parameter Setting Unit

Pr. 37 Setting

Pr. 144 Setting

Monitor Display

Running Speed Setting Unit

 

 

Speed of 4-pole motor (r/min)

 

0

0

 

Hz

0

2 to 10

Motor speed (r/min)

 

1 to 9998

102 to 110

 

r/min

0

102 to 110

Machine speed

Hz

1 to 9998

0

r/min

1 to 9998

2 to 10

 

Note: 1. In the V/F control mode, the motor speed is converted from the output frequency and does not match the actual speed.

2.When the running speed display has been selected with "0" set in Pr. 37 and "0" in Pr. 144, the monitor display shows the speed reference for a 4-pole motor (1800r/min is displayed at 60Hz).

3.To change the PU main monitor (PU main display) or PU level meter (PU level display), refer to Pr. 52 and Pr. 53.

4.As the operation panel display is 4 digits, "----" is displayed when the monitored value exceeds "9999".

CAUTION

Make sure that the running speed and number of poles set are correct. Otherwise, the motor might run at extremely high speed, damaging the machine.

82