PARAMETERS

 

 

 

 

 

 

Minimum

Factory

Refer

Cust-

Func-

Parameter

 

 

Setting

omer

Name

Setting Range

Setting

To

tion

Number

EC

Set-

 

 

Increments

Page:

 

 

 

 

 

 

Version

ting

 

 

 

 

 

 

 

 

Output terminal

functions

 

41

Up-to-frequency sensitivity

0 to 100%

0.1%

10%

83

 

 

 

 

 

 

 

 

 

 

43

 

0 to 120Hz, 9999

0.01Hz

9999

84

 

 

 

 

42

Output frequency detection

0 to 120Hz

0.01Hz

6Hz

84

 

 

 

 

 

Output frequency detection for reverse

 

 

 

 

 

 

 

 

 

rotation

 

 

 

 

 

 

 

 

44

Second acceleration/deceleration time

0 to 3600 s/

0.1 s/0.01 s

5 s

70

 

 

 

 

0 to 360 s

 

 

 

 

 

 

 

 

 

 

functions

 

 

45

Second deceleration time

0 to 3600 s/0 to 360 s,

0.1 s/0.01 s

9999

70

 

 

 

9999

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

46

Second torque boost

0 to 30%, 9999

0.1%

9999

66

 

Second

 

 

47

Second V/F (base frequency)

0 to 120Hz, 9999

0.01Hz

9999

68

 

 

 

48

Second stall prevention operation current

0 to 150%

0.1%

120%

85

 

 

 

49

Second stall prevention operation

0 to 120Hz, 9999

0.01

0

85

 

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

50

Second output frequency detection

0 to 120Hz

0.01Hz

30Hz

84

 

 

 

$

52

DU/PU main display data selection

0, 5, 6, 8, 10 to 14, 17,

1

0

86

 

 

 

20, 23, 24, 25, 100

 

 

 

 

 

 

 

 

 

 

functions

 

$

53

PU level display data selection

0 to 3, 5, 6, 8, 10 to 14,

1

1

86

 

 

17

 

 

 

 

 

 

 

 

 

 

 

$

54

FM terminal function selection

1 to 3, 5, 6, 8, 10 to 14,

1

1

86

 

 

 

17, 21

 

Display

 

 

 

 

 

 

 

 

 

$

55

Frequency monitoring reference

0 to 120Hz

0.01Hz

60Hz

88

 

 

 

 

 

 

50Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated

 

 

 

 

$

56

Current monitoring reference

0 to 500A

0.01A

output

88

 

 

 

 

 

 

 

 

current

 

 

Automatic restart

functions

$

58

Restart cushion time

0 to 60 s

0.1 s

1.0 s

89

 

 

 

$

57

Restart coasting time

0, 0.1 to 5 s, 9999

0.1 s

9999

89

 

 

 

 

 

 

 

 

 

 

Additional function

 

59

Remote setting function selection

0, 1, 2

1

0

91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

$

60

Intelligent mode selection

0, 3, 4, 9

1

0

93

 

 

 

 

61

Reference I for intelligent mode

0 to 500A, 9999

0.01A

9999

94

 

 

 

 

62

Ref. I for intelligent mode accel.

0 to 150%, 9999

0.1%

9999

94

 

 

 

 

63

Ref. I for intelligent mode decel.

0 to 150%, 9999

0.1%

9999

94

 

 

 

$

65

Retry selection

0 to 5

1

0

95

 

functions

 

$

66

Stall prevention operation level reduction

0 to 120Hz

0.01Hz

60Hz

77

 

 

starting frequency

50Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

$

67

Number of retries at alarm occurrence

0 to 10,101 to 110

1

0

95

 

selection

 

$

68

Retry waiting time

0 to 10 s

0.1 s

1 s

95

 

 

$

69

Retry count display erasure

0



0

95

 

 

 

 

 

 

$

71

Applied motor

0, 1, 2

1

0

97

 

Operation

 

$

72

PWM frequency selection

0 to 15

1

2

98

 

 

$

73

0-5V/0-10V selection

0 to 5, 10 to 15

1

1

99

 

 

 

 

 

 

$

74

Filter time constant

0 to 8

1

1

100

 

 

 

$

75

Reset selection/disconnected PU

0 to 3, 14 to 17

1

14

100

 

 

 

detection/PU stop selection

 

 

 

 

 

 

 

 

 

 

 

 

$

76

Alarm code output selection

0, 1, 2

1

0

102

 

 

 

$

77

Parameter write disable selection

0, 1, 2

1

0

103

 

 

 

$

78

Reverse rotation prevention selection

0, 1,

1

0

104

 

 

 

$

79

Operation mode selection

0 to 4, 6 to 8

1

0

105

 

flexiblepoint-5 V/F characteristics

 

100

V/F1 (first frequency)

0 to 120Hz, 9999

0.01Hz

9999

108

 

 

101

V/F1 (first frequency voltage)

0 to 1000V

0.1V

0

108

 

 

102

V/F2 (second frequency)

0 to 120Hz, 9999

0.01Hz

9999

108

 

 

 

 

 

 

 

 

103

V/F2 (second frequency voltage)

0 to 1000V

0.1V

0

108

 

 

 

 

104

V/F3 (third frequency)

0 to 120Hz, 9999

0.01Hz

9999

108

 

 

 

 

105

V/F3 (third frequency voltage)

0 to 1000V

0.1V

0

108

 

 

 

 

106

V/F4 (fourth frequency)

0 to 120Hz, 9999

0.01Hz

9999

108

 