PROTECTIVE FUNCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Panel

 

oL

 

 

 

FR-PU04

 

oL

 

 

Indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

Stall prevention (overvoltage)

 

 

 

 

 

 

 

 

 

 

If the regenerative energy of the motor increases too much

 

 

 

During

 

to exceed the brake capability, this function stops the

 

 

Description

 

decrease in frequency to prevent overvoltage shut-off. As

 

 

deceleration

 

 

 

 

 

soon as the regenerative energy has reduced, deceleration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

resumes.

 

 

 

 

 

Check point

Check for sudden speed reduction.

 

 

 

 

Corrective action

The deceleration time may change. Increase the deceleration time with Pr. 8

 

 

"deceleration time".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Panel

 

PS

 

 

 

FR-PU04

 

PS

 

 

Indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

PU stop

 

 

 

 

 

 

 

 

A stop made by pressing the

STOP

key of the PU has been set in Pr. 75 "PU

 

 

Description

RESET

 

 

stop selection".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check point

Check for a stop made by pressing the

STOP

key of the operation panel.

 

 

RESET

 

 

 

 

 

 

 

 

 

 

 

Corrective action

Refer to page 100.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Panel

 

TH

 

 

 

FR-PU04

 

TH

 

 

Indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name

Electronic overcurrent protection prealarm

 

 

 

 

This alarm appears if the cumulative value of the electronic overcurrent

 

 

Description

protection reaches 85% of the preset level. If it reaches 100% of the preset

 

 

 

level, motor overload shutoff (E.THM) occurs.

 

 

 

Check point

Check for large load or sudden acceleration.

 

 

 

Corrective action

Reduce the load volume or the frequency of operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation Panel

 

Err.

 

 

 

 

 

 

 

 

 

Indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This alarm appears if:

 

 

 

 

 

 

The RES signal is on.

 

 

 

 

 

 

You attempted to set any parameter value in the external operation mode.

 

 

 

You attempted to change the operation mode during operation.

 

 

Description

You attempted to set any parameter value outside its setting range.

 

 

 

You attempted to set any parameter value during operation

 

 

 

 

(while signal STF or STR is ON).

 

 

 

 

 

You attempted to make parameter setting when Pr. 77 "parameter write

 

 

 

 

disable selection" has been set to disable parameter write.

 

 

Corrective action

Perform operation correctly.

 

 

 

 

171

Page 185
Image 185
Mitsumi electronic FR-F520-0.75K PU stop Stop made by pressing, Key of the PU has been set in Pr PU, Stop selection, Err