Mitsumi electronic 55K, FR-F520-0.75K instruction manual Parameter setting method

Models: FR-F520-0.75K 55K

1 217
Download 217 pages 2.41 Kb
Page 60
Image 60

OPERATION/CONTROL

3.2.5Parameter setting method

A parameter value may either be set by updating its parameter number or setting the value digit-by-digit

using the key.

To write the setting, change it and press the SET key 1.5 seconds.

Example: To change the Pr. 79 "operation mode selection" setting from "2" (external operation mode) to "1" (PU operation mode)

(For details of Pr.79, refer to page 105.) Press the MODE key, to choose the parameter setting mode.

#Parameter setting mode

FR-DU04

CONTROL PANEL

 

Most significant

 

 

Least significant

 

 

 

Hz

 

 

 

 

 

 

 

digit flickers

 

Middle digit flickers

digit flickers

 

 

 

A

 

 

 

 

 

V

SET

SET

 

 

 

 

 

 

 

MON

EXT

 

PU

 

 

 

 

 

 

REV

 

FWD

 

 

 

 

 

 

MODE

To 3.2.6 Operation mode

7 times or

3 times

9 times or

1 times

#Current setting

#Setting change

0 to 9

SET

0 to 9

SET

 

 

Press for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.5 s

 

 

 

 

 

 

 

 

 

3

 

 

SET

 

 

 

 

 

 

 

 

 

 

#Setting write

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MON EXT

 

PU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When

appears

 

 

REV

 

FWD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) When the [FWD] or [REV] indication is lit,

 

 

stop operation by pressing the

STOP

 

key

 

 

RESET

 

 

 

or turning off the forward rotation (STF)

 

 

 

 

or reverse rotation (STR) signal connected

Flicker

 

to the control terminal.

 

 

 

 

 

2)You cannot set any value that is outside the parameter setting range. Write a value within the setting range.

"1" (PU operation mode) has been set in Pr. 79.

If the value and do not flicker but appears, you did not press the SET key

for 1.5 seconds when writing the value.

Press the key once, press the SET key, and restart the setting from the beginning.

48

Page 60
Image 60