Mitsumi electronic FR-F520-0.75K, 55K instruction manual PWM carrier frequency Pr , Pr

Models: FR-F520-0.75K 55K

1 217
Download 217 pages 2.41 Kb
Page 111
Image 111

PARAMETERS

4.2.30 PWM carrier frequency (Pr. 72, Pr. 240)

Pr. 72 "PWM frequency selection"

Pr. 240 "Soft-PWM setting"

You can change the motor tone.

#By parameter setting, you can select Soft-PWM control which changes the motor tone.

#Soft-PWM control changes motor noise from a metallic tone into an unoffending complex tone.

Parameter

Factory

Setting Range

Remarks

Number

Setting

 

 

72

2

0 to 15

0: 0.7kHz, 15: 14.5kHz

240

1

0, 1

1: Soft-PWM valid

<Setting>

Refer to the following list and set the parameters:

Parameter

Factory Setting

Description

Number

 

 

72

0 to 15

PWM carrier frequency can be changed.

The setting displayed is in [kHz]. Note that 0 indicates 0.7kHz and 15 indicates 14.5kHz.

 

 

240

0

Soft-PWM invalid

1

When any of "0 to 5" is set in Pr. 72, Soft-PWM is made valid.

 

Note: 1. A reduced PWM carrier frequency will decrease inverter-generated noise and leakage current but increase motor noise.

2.If the PWM carrier frequency is increased to make noise low, continuous operation performed at more than 75% of the rated current may generate motor noise, but this is not an error.