PARAMETERS

Note: 1. If the Pr. 903 or Pr. 905 (gain adjustment) value is changed, the Pr. 20 value does not change. The input signal to terminal 1 (frequency setting auxiliary input) is added to the frequency setting signal.

2.For the operation procedure using the parameter unit (FR-PU04), refer to the FR-PU04 instruction manual.

CAUTION

Be careful when setting the bias frequency at 0V to any value other than "0". Even without the speed command, the motor will start running at the set frequency by merely switching on the start signal.

4.2.57 Buzzer control (Pr. 990)

Pr. 990 "buzzer control"

You can make the buzzer "beep" when you press any key of the operation panel or parameter unit.

Parameter

Factory

Setting Range

Remarks

Number

Setting

 

 

990

1

0, 1

0: Without beep, 1: With beep

162