4.2.49 Output terminal function selection (Pr. 190 to Pr. 195)

Pr. 190 "RUN terminal function selection"

Pr. 191 "SU terminal function selection"

Pr. 192 "IPF terminal function selection"

Pr. 193 "OL terminal function selection"

Pr. 194 "FU terminal function selection"

Pr. 195 "A, B, C terminal function selection"

You can change the functions of the open collector and contact output terminals.

Parameter

Terminal

Factory

Factory-Set

Setting Range

Number

Symbol

Setting

Terminal Function

 

190

RUN

0

Inverter running

0 to 5, 8, 10, 11,

191

SU

1

Up to frequency

13 to 19, 25, 26,

192

IPF

2

Instantaneous power

98 to 105, 108,

failure/undervoltage

110, 111,

 

 

 

193

OL

3

Overload alarm

113 to 116,

194

FU

4

Output frequency

125, 126, 198,

detedtion

199, 9999

 

 

 

195

A, B, C

99

Alarm output

(40 to 48 Note)

Note: Setting may be made for the NA and EC versions only.

<Setting>

Refer to the following table and set the parameters:

Setting

Signal

 

 

Related

Positive

Negative

Function

Operation

Name

parameter

logic

logic

 

 

 

 

 

 

0

100

RUN

Inverter running

Output during operation when the inverter output



frequency rises to or above the starting frequency.

 

 

 

 

 

1

101

SU

Up to frequency

Refer to Pr. 41 "up-to-frequency sensitivity". (Note

Pr. 41

1)

 

 

 

 

 

2

102

IPF

Instantaneous power failure or

Output when an instantaneous power failure or



undervoltage

undervoltage occurs.

 

 

 

 

 

 

 

 

 

Pr. 22, Pr. 23,

3

103

OL

Overload alarm

Output while stall prevention function is activated.

Pr. 66, Pr. 148,

 

 

 

 

 

Pr. 149,Pr. 154

4

104

FU

Output frequency detection

Refer to Pr. 42, Pr. 43 (output frequency

Pr. 42, Pr. 43

detection).

 

 

 

 

 

5

105

FU2

Second output frequency

Refer to Pr. 50 (second output frequency

Pr. 50

detection

detection).

 

 

 

 

 

 

 

Electronic overcurrent

Output when the cumulative electronic

 

8

108

THP

overcurrent protection value reaches 85% of the

Pr. 9

protection pre-alarm

 

 

 

preset level.

 

 

 

 

 

 

10

110

PU

PU operation mode

Output when the PU operation mode is selected.



11

111

RY

Inverter operation ready

Output when the inverter can be started by



switching the start signal on or while it is running.

 

 

 

 

 

13

113

Y13

Zero current detection

Refer to Pr. 152 and Pr. 153 (zero current

Pr. 152, Pr. 153

detection).

 

 

 

 

 

14

114

FDN

PID lower limit

 

 

15

115

FUP

PID upper limit

Refer to Pr. 128 to Pr. 134 (PID control).

Pr. 128 to

16

116

RL

PID forward-reverse rotation

Pr. 134

 

output

 

 

 

 

 

 

 

140

Page 153